Back to Search Start Over

Failure to Rescue - a Closer Look at Mortality Rates Has No Added Value for Hospital Comparisons but Is Useful for Team Quality Assessment in Abdominal Aortic Aneurysm Surgery in The Netherlands.

Authors :
Lijftogt N
Karthaus EG
Vahl A
van Zwet EW
van der Willik EM
Tollenaar RAEM
Hamming JF
Wouters MWJM
Source :
European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery [Eur J Vasc Endovasc Surg] 2018 Nov; Vol. 56 (5), pp. 652-661. Date of Electronic Publication: 2018 Aug 23.
Publication Year :
2018

Abstract

Objectives: Failure to rescue (FTR) is a composite quality indicator, defined as the proportion of deceased patients following major complications. The aims of this study were to compare FTR with mortality for hospital comparisons in abdominal aortic aneurysm (AAA) surgery in The Netherlands and investigate hospital volume and associated factors.<br />Methods: Patients prospectively registered between 2013 and 2015 in the Dutch Surgical Aneurysm Audit (DSAA) were analysed. FTR was analysed for AAA patients and subgroups elective (EAAA) and acute (AAAA; symptomatic or ruptured) aneurysms. Variables and hospital volume were analysed by uni- and multivariable regression analysis. Adjusted hospital comparisons for mortality, major complications, and FTR were presented in funnel plots. Isomortality lines were constructed when presenting FTR and major complication rates.<br />Results: A total of 9258 patients were analysed in 61 hospitals: 7149 EAAA patients (77.2%) and 2109 AAAA patients (22.8%). There were 2785 (30.1%) patients with complications (unadjusted range 5-65% per hospital): 2161 (77.6%) with major and 624 (28.4%) patients with minor complications. Overall mortality was 6.6% (adjusted range 0-16% per hospital) and FTR was 28.4% (n = 613) (adjusted range 0-60% per hospital). Glasgow Coma Scale, age, pulse, creatinine, electrocardiography, and operative setting were independently associated with FTR. Hospital volume was not associated with FTR. In AAAA patients hospital volume was significantly associated with a lower adjusted major complication and mortality rate (OR 0.62, 95% CI 0.49-0.78; and 0.64, 95% CI 0.48-0.87). Four hospitals had a significant lower adjusted FTR with different major complication rates on different isomortality lines.<br />Conclusions: There was more variation in FTR than in mortality between hospitals. FTR identified the same best performing hospitals as for mortality and therefore was of limited additional value in measuring quality of care for AAA surgery. FTR can be used for internal quality improvement with major complications in funnel plots and diagrams with isomortality lines.<br /> (Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1532-2165
Volume :
56
Issue :
5
Database :
MEDLINE
Journal :
European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery
Publication Type :
Academic Journal
Accession number :
30145163
Full Text :
https://doi.org/10.1016/j.ejvs.2018.06.062