Back to Search
Start Over
Functional Outcomes of Type I Bicuspid Aortic Valve Repair With Annular Stabilization: Subcommissural Annuloplasty Versus External Subannular Aortic Ring.
- Source :
-
The Annals of thoracic surgery [Ann Thorac Surg] 2019 Jan; Vol. 107 (1), pp. 68-75. Date of Electronic Publication: 2018 Aug 04. - Publication Year :
- 2019
-
Abstract
- Background: In bicuspid aortic valve patients with nonaneurysmal root (<45 mm) and severe aortic insufficiency (AI), external subannular aortic ring (ESAR) is being increasingly utilized for annular stabilization, compared with traditional subcommissural annuloplasty (SCA). To this date, there is no comparative study assessing functional equivalence or superiority of ESAR over SCA.<br />Methods: From 2003 to 2017, 139 patients underwent type I bicuspid aortic valve repair, of which 50 patients underwent concomitant SCA and 24 underwent ESAR. Cases with suboptimal echocardiographic imaging were excluded, resulting in 38 patients in the SCA group and 20 patients in ESAR group. Intraoperative transesophageal echocardiography before and after procedure were retrospectively analyzed for 11 parameters in the functional aortic root complex.<br />Results: ESAR patients had larger preoperative annulus (28.3 ± 3.2 mm versus 29.8 ± 3.7 mm, p = 0.1) and left ventricular (LV) outflow tract (28.1 ± 3.5 mm versus 29.8 ± 4.0 mm, p = 0.1) diameters, with greater leaflet prolapse (3.4 ± 1.3 mm versus 4.3 ± 1.3, p = 0.02). In both groups, 100% freedom from AI greater than 1+ was achieved, with significant reduction of vena contracta (-3.0 ± 0.6 mm, p < 0.001; -3.2 ± 0.4 mm, p < 0.001) and level of eccentricity of AI jet (AI angle change: -24.3 ± 6.5 degrees, p = 0.002; -22.3 ± 7.2 degrees, p = 0.01). Reduction in LV dimensions (-7.1 ± 1.2 mm, p < 0.001; -8.9 ± 1.9 mm, p < 0.001), annulus (-3.4 ± 0.4 mm, p < 0.001; -5.1 ± 2.7 mm, p < 0.001), LV outflow tract (-2.3 ± 0.4 mm, p < 0.001; -4.4 ± 0.5 mm, p < 0.001), and degree of leaflet prolapse (-1.6 ± 0.4 mm, p = 0.005; -2.1 ± 0.4 mm, p = 0.001) was achieved in both groups. Comparison of postprocedure outcomes showed improved mean transvalvular gradients in ESAR (11.2 ± 5.7 mm Hg versus 7.1 ± 2.5 mm Hg, p = 0.003), with similar freedom from AI.<br />Conclusions: In addition to providing equivalent and excellent freedom from AI, ESAR also renders a more robust annular reduction than SCA, along with improved transvalvular gradients.<br /> (Copyright © 2019 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Adult
Aortic Valve surgery
Aortic Valve Insufficiency etiology
Aortic Valve Insufficiency mortality
Bicuspid Aortic Valve Disease
Echocardiography, Transesophageal
Female
Heart Valve Diseases complications
Heart Valve Diseases mortality
Humans
Male
Middle Aged
Recovery of Function
Retrospective Studies
Treatment Outcome
Aortic Valve abnormalities
Aortic Valve Insufficiency surgery
Cardiac Valve Annuloplasty
Heart Valve Diseases surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1552-6259
- Volume :
- 107
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- The Annals of thoracic surgery
- Publication Type :
- Academic Journal
- Accession number :
- 30086284
- Full Text :
- https://doi.org/10.1016/j.athoracsur.2018.06.056