Back to Search Start Over

Safety and complications after three different surface ablation techniques with mitomycin C: a retrospective analysis of 2757 eyes.

Authors :
Mehlan J
Linke SJ
Skevas C
Steinberg J
Giannakakis K
Katz T
Source :
Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie [Graefes Arch Clin Exp Ophthalmol] 2019 Jan; Vol. 257 (1), pp. 217-223. Date of Electronic Publication: 2018 Aug 03.
Publication Year :
2019

Abstract

Background: To evaluate the safety and spectrum of complications of three excimer laser surface ablation techniques (SATs) with an intraoperative application of mitomycin C (MMC) 0.02%. A retrospective, non-comparative large case series.<br />Methods: SATs were performed on 2757 eyes with a preoperative spherical equivalent (SE) of - 4.41 ± 2.44 and a Wavelight Allegretto 200 platform. Ablation zone diameters between 6.0 and 7.0 mm were used according to mesopic pupil size. All patients were treated with an intraoperative application of MMC for 30 to 90 s depending on refractive error. The mean follow-up time was > 3 months (107 ± 24 days). Complication range and incidence were analyzed retrospectively and safety index was calculated.<br />Results: Two thousand seven hundred and fifty-seven eyes met the inclusion criteria for surface ablation. Two thousand five hundred and seventy-three eyes were assigned to alcohol-assisted photorefractive keratectomy (APRK), 135 eyes to transepithelial photorefractive keratectomy (TPRK), and 49 eyes to off-flap epithelial laser in situ keratomileusis (EpiLASIK/EpiK). Overall, the safety index was 1.06 ± 0.28. Haze was graded according to the Fantes scale. Haze incidence rates were highest in the TPRK group (14.81%) and comparably low in APRK (2.95%) and EpiK (4.08%) groups.<br />Conclusions: Intraoperative topical application of MMC (0.02%) results in good safety and no severe side effects. However, highest incidence of haze was observed after TPRK. The more frequent peripheral localization of haze might be attributed to large ablation zones and the wavefront optimized ablation profile especially in the PTK modus of the laser platform.

Details

Language :
English
ISSN :
1435-702X
Volume :
257
Issue :
1
Database :
MEDLINE
Journal :
Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie
Publication Type :
Academic Journal
Accession number :
30076471
Full Text :
https://doi.org/10.1007/s00417-018-4077-7