Back to Search Start Over

Ranolazine in High-Risk Patients With Implanted Cardioverter-Defibrillators: The RAID Trial.

Authors :
Zareba W
Daubert JP
Beck CA
Huang DT
Alexis JD
Brown MW
Pyykkonen K
McNitt S
Oakes D
Feng C
Aktas MK
Ayala-Parades F
Baranchuk A
Dubuc M
Haigney M
Mazur A
McPherson CA
Mitchell LB
Natale A
Piccini JP
Raitt M
Rashtian MY
Schuger C
Winters S
Worley SJ
Ziv O
Moss AJ
Source :
Journal of the American College of Cardiology [J Am Coll Cardiol] 2018 Aug 07; Vol. 72 (6), pp. 636-645.
Publication Year :
2018

Abstract

Background: Ventricular tachycardia (VT) and ventricular fibrillation (VF) remain a challenging problem in patients with implantable cardioverter-defibrillators (ICDs).<br />Objectives: This study aimed to determine whether ranolazine administration decreases the likelihood of VT, VF, or death in patients with an ICD.<br />Methods: This was double-blind, placebo-controlled clinical trial in which high-risk ICD patients with ischemic or nonischemic cardiomyopathy were randomized to 1,000 mg ranolazine twice a day or placebo. The primary endpoint was VT or VF requiring appropriate ICD therapy or death, whichever occurred first. Pre-specified secondary endpoints included ICD shock for VT, VF, or death and recurrent VT or VF requiring ICD therapy.<br />Results: Among 1,012 ICD patients (510 randomized to ranolazine and 502 to placebo) the mean age was 64 ± 10 years and 18% were women. During 28 ± 16 months of follow-up there were 372 (37%) patients with primary endpoint, 270 (27%) patients with VT or VF, and 148 (15%) deaths. The blinded study drug was discontinued in 199 (39.6%) patients receiving placebo and in 253 (49.6%) patients receiving ranolazine (p = 0.001). The hazard ratio for ranolazine versus placebo was 0.84 (95% confidence interval: 0.67 to 1.05; p = 0.117) for VT, VF, or death. In a pre-specified secondary analysis, patients randomized to ranolazine had a marginally significant lower risk of ICD therapies for recurrent VT or VF (hazard ratio: 0.70; 95% confidence interval: 0.51 to 0.96; p = 0.028). There were no other significant treatment effects in other pre-specified secondary analyses, which included individual components of the primary endpoint, inappropriate shocks, cardiac hospitalizations, and quality of life.<br />Conclusions: In high-risk ICD patients, treatment with ranolazine did not significantly reduce the incidence of the first VT or VF, or death. However, the study was underpowered to detect a difference in the primary endpoint. In prespecified secondary endpoint analyses, ranolazine administration was associated with a significant reduction in recurrent VT or VF requiring ICD therapy without evidence for increased mortality. (Ranolazine Implantable Cardioverter-Defibrillator Trial [RAID]; NCT01215253).<br /> (Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1558-3597
Volume :
72
Issue :
6
Database :
MEDLINE
Journal :
Journal of the American College of Cardiology
Publication Type :
Academic Journal
Accession number :
30071993
Full Text :
https://doi.org/10.1016/j.jacc.2018.04.086