Atrioventricular optimization in cardiac resynchronization therapy with quadripolar leads: should we optimize every pacing configuration including multi-point pacing?

Authors :
van Everdingen WM
Zweerink A
Salden OAE
Cramer MJ
Doevendans PA
van Rossum AC
Prinzen FW
Vernooy K
Allaart CP
Meine M
Source :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2019 Jan 01; Vol. 21 (1), pp. e11-e19.
Publication Year :
2019

Abstract

Aims: This study aims to define an atrioventricular (AV) delay optimization method for cardiac resynchronization therapy (CRT) with a quadripolar left ventricular (LV) lead based on intrinsic conduction intervals.<br />Methods and Results: Heart failure patients with a left bundle branch block underwent CRT implantation with a quadripolar LV lead. Invasive LV pressure-volume loops were recorded during four biventricular and three multi-point pacing (MPP) settings, using four patient-specific paced AV delays. Haemodynamic response was defined as change in stroke work (Δ%SW) compared to intrinsic rhythm and was related to the following conduction intervals: right atrial pacing to right ventricular sensing interval (RAp-RVs), Q to LV sensing interval normalized to QRS duration (QLV/QRSd), PR-interval, and P-wave duration. In 44 patients, the largest Δ%SW (104 ± 76%) occurred at a paced AV delay of 128 ± 32 ms, at 47 ± 9% of RAp-RVs. Optimal AV delay of biventricular pacing (126 ± 26 ms) did not differ from MPP (126 ± 21 ms, P = 0.29). Intra-class correlation coefficient between optimal AV delays of different pacing configurations was 0.64 (0.45-0.78, P < 0.001). Although not statistically significant, Δ%SW at 50% of RAp-RVs (98 ± 74%) was closer to the maximal achievable Δ%SW increase than a fixed interval of 120 ms (96 ± 73%, P = 0.60). RAp-RVs, QLV/QRSd, PR interval, and P-wave duration were associated with the optimal AV delay in univariate analysis, but only RAp-RVs remained significantly associated in multivariate analysis (R = 0.69).<br />Conclusion: The AV delay that provides highest haemodynamic response is similar for various LV pacing configurations and for MPP. An AV delay ∼50% of RAp-RVs creates an acute haemodynamic response close to the maximal patient-specific response.

Details

Language :
English
ISSN :
1532-2092
Volume :
21
Issue :
1
Database :
MEDLINE
Journal :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
Publication Type :
Academic Journal
Accession number :
30052906
Full Text :
https://doi.org/10.1093/europace/euy138