Back to Search Start Over

Emptying cystometry: A feasibility and validation pilot study on female patients.

Authors :
Chesnel C
Charlanes A
Declemy A
Le Breton F
Kerdraon J
Sheikh Ismael S
Amarenco G
Source :
Progres en urologie : journal de l'Association francaise d'urologie et de la Societe francaise d'urologie [Prog Urol] 2018 Sep; Vol. 28 (11), pp. 542-547. Date of Electronic Publication: 2018 Jul 14.
Publication Year :
2018

Abstract

Introduction: To assess the feasibility and the accuracy of emptying cystometry in order to simplify the manometric follow-up of overactive detrusor in neurological patients under anticholinergic or botulinum toxin injections.<br />Material: Female patients with a stable detrusor underwent both a conventional cystometry and sequential measurements of bladder pressure during emptying (emptying cystometry). At the end of the standard cystometry, a CH12 urinary catheter was introduced in the bladder and was connected to a three-way stopcock. The second way of the stopcock permitted the emptying. The third way of the stopcock was connected to a vertical graduated tube to measure the bladder pressure each 50mL during the bladder emptying.<br />Results: Eleven female patients were included (mean age: 59.4years). Nine patients (82%) had neurogenic bladder. Mean cystometric capacity was 439mL (SD: 35mL). During the emptying cystometry, 8 to 10 measures were taken (mean: 9.4). The mean detrusor pressure was 1.7cmH <subscript>2</subscript> O (SD 2.1) for the filling cystometry and 2.3cmH <subscript>2</subscript> O (SD: 2.7) for the emptying cystometry. The agreement between the detrusor pressure between the two cystometries was good with intra-class correlation coefficient at 0.66 [0.48-0.77] - and the correlation was high (r=0.7; P<0.000001).<br />Conclusion: In a small, selected sample of patients, emptying cystometry provides similar results of detrusor pressure to filling cystometry. This technique could constitute a home monitoring of bladder pressures in a selected population of patients with intermittent catheterization in whom a manometric follow-up of detrusor overactivity is required.<br />Level of Evidence: 4.<br /> (Copyright © 2018 Elsevier Masson SAS. All rights reserved.)

Details

Language :
English
ISSN :
1166-7087
Volume :
28
Issue :
11
Database :
MEDLINE
Journal :
Progres en urologie : journal de l'Association francaise d'urologie et de la Societe francaise d'urologie
Publication Type :
Academic Journal
Accession number :
30017704
Full Text :
https://doi.org/10.1016/j.purol.2018.06.008