Back to Search Start Over

Low-voltage (80-kVp) abdominopelvic computed tomography allows 60% contrast dose reduction in patients at risk of contrast-induced nephropathy.

Authors :
Araki K
Yoshizako T
Yoshida R
Tada K
Kitagaki H
Source :
Clinical imaging [Clin Imaging] 2018 Sep - Oct; Vol. 51, pp. 352-355. Date of Electronic Publication: 2018 Jun 09.
Publication Year :
2018

Abstract

Purpose: The purpose of this study was to evaluate the quality of image in abdominopelvic late phase computed tomography (CT) with a low tube voltage plus low dose contrast medium (CM) protocol (80-kVp, 60% CM). A compared with the conventional protocol (120-kVp, 100% CM) B in the same patients.<br />Material and Methods: This study included with 22 patients {36 to 77 kg (mean: 55.5 kg)} who had renal insufficiency and had experience of performance conventional CT without renal insufficiency during pre-18 months. The CT value of the portal vein, liver parenchyma, abdominal aorta, psoas muscle was measured. The estimated mean CNR (contrast-to-noise ratios), FOM (figure of merit), DLP (dose length product) and ED (effective dose) were compared between protocol A and B. Moreover, two radiologists assessed the visual quality of the CT images.<br />Results: The mean DLP and ED in the protocol B was about 50% lower than that in the protocol A (p < 0.01). The mean CT value of the portal vein and abdominal aorta in the protocol B were significantly higher than that in the protocol A (p < 0.01). All of the FOM in the protocol B was significantly higher than that in the protocol A (p < 0.01). However, there was no significant difference in the mean CNR and visual quality between protocol A and B.<br />Conclusion: Performance of abdominopelvic CT using a low tube voltage plus reduced CM dose (80-kVp, 60% CM) achieved reduction of the radiation dose without impairing image quality in relatively light weight group.<br />Clinical Relevance/application: In abdominopelvic CT, protocol of low tube voltage (80-kVp) plus iodine dose reduction (60%) is able to provide the same quality of traditional protocols, also able to reducing radiation exposure (50%).<br /> (Copyright © 2018 Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1873-4499
Volume :
51
Database :
MEDLINE
Journal :
Clinical imaging
Publication Type :
Academic Journal
Accession number :
29982133
Full Text :
https://doi.org/10.1016/j.clinimag.2018.05.027