Back to Search
Start Over
Rapid Antibiotic Combination Testing for Carbapenem-Resistant Gram-Negative Bacteria within Six Hours Using ATP Bioluminescence.
- Source :
-
Antimicrobial agents and chemotherapy [Antimicrob Agents Chemother] 2018 Aug 27; Vol. 62 (9). Date of Electronic Publication: 2018 Aug 27 (Print Publication: 2018). - Publication Year :
- 2018
-
Abstract
- To guide the timely selection of antibiotic combinations against carbapenem-resistant Gram-negative bacteria (CR-GNB), an in vitro test with a short turnaround time is essential. We developed an in vitro ATP bioluminescence assay to determine effective antibiotic combinations against CR-GNB within 6 h. We tested 42 clinical CR-GNB strains (14 Acinetobacter baumannii , 14 Pseudomonas aeruginosa , and 14 Klebsiella pneumoniae strains) against 74 single antibiotics and two-antibiotic combinations. Bacteria (approximately 5 log <subscript>10</subscript> CFU/ml) were incubated with an antibiotic(s) at 35°C; ATP bioluminescence was measured at 6 h and 24 h; and the measurements were compared to viable counts at 24 h. Receiver operating characteristic (ROC) curves were used to determine the optimal luminescence thresholds ( T <subscript>RLU</subscript> ) for distinguishing between inhibitory and noninhibitory combinations. The areas under the 6-h and 24-h ROC curves were compared using the DeLong method. Prospective validation of the established thresholds was conducted using 18 additional CR-GNB. The predictive accuracy of T <subscript>RLU</subscript> for the 6-h ATP bioluminescence assay was 77.5% when all species were analyzed collectively. Predictive accuracies ranged from 73.7% to 82.7% when each species was analyzed individually. Upon comparison of the areas under the 6-h and 24-h ROC curves, the 6-h assay performed significantly better than the 24-h assay ( P < 0.01). Predictive accuracy remained high upon prospective validation of the 6-h ATP assay (predictive accuracy, 79.8%; 95% confidence interval [CI], 77.6 to 81.9%), confirming the external validity of the assay. Our findings indicate that our 6-h ATP bioluminescence assay can provide guidance for prospective selection of antibiotic combinations against CR-GNB in a timely manner and may be useful in the management of CR-GNB infections.<br /> (Copyright © 2018 American Society for Microbiology.)
- Subjects :
- Gram-Negative Bacteria metabolism
Gram-Negative Bacterial Infections metabolism
Humans
Luminescent Measurements methods
Prospective Studies
Adenosine Triphosphate metabolism
Anti-Bacterial Agents pharmacology
Carbapenems pharmacology
Drug Resistance, Multiple, Bacterial drug effects
Gram-Negative Bacteria drug effects
Gram-Negative Bacterial Infections drug therapy
Subjects
Details
- Language :
- English
- ISSN :
- 1098-6596
- Volume :
- 62
- Issue :
- 9
- Database :
- MEDLINE
- Journal :
- Antimicrobial agents and chemotherapy
- Publication Type :
- Academic Journal
- Accession number :
- 29967021
- Full Text :
- https://doi.org/10.1128/AAC.00183-18