Performance of Vitek MS v3.0 for Identification of Mycobacterium Species from Patient Samples by Use of Automated Liquid Medium Systems.

Authors :
Miller E
Cantrell C
Beard M
Derylak A
Babady NE
McMillen T
Miranda E
Body B
Tang YW
Vasireddy R
Vasireddy S
Smith T
Iakhiaeva E
Wallace RJ Jr
Brown-Elliott BA
Moreno E
Totty H
Deol P
Source :
Journal of clinical microbiology [J Clin Microbiol] 2018 Jul 26; Vol. 56 (8). Date of Electronic Publication: 2018 Jul 26 (Print Publication: 2018).
Publication Year :
2018

Abstract

The accuracy and robustness of the Vitek MS v3.0 matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) system was evaluated by identifying mycobacteria from automated liquid-medium systems using patient samples. This is the first report to demonstrate that proteins within the liquid medium, its supplements, and decontamination reagents for nonsterile patient samples do not generate misidentification or false-positive results by use of the Vitek MS v3.0 system. Prior to testing with patient samples, a seeded-culture study was conducted to challenge the accuracy of the Vitek MS system at identifying mycobacteria from liquid medium by mimicking a clinical workflow. Seventy-seven Mycobacterium strains representing 21 species, seeded in simulated sputum, were decontaminated, inoculated into BacT/Alert MP liquid culture medium, incubated until positivity, and identified using the Vitek MS system. A total of 383 liquid cultures were tested, of which 379 (99%) were identified correctly to the species/complex/group level, 4 (1%) gave a "no-identification" result, and no misidentifications were observed. Following the simulated-sputum study, a total of 73 smear-positive liquid-medium cultures detected using BD BBL MGIT and VersaTREK Myco liquid media were identified by the Vitek MS system. Sixty-four cultures (87.7%) were correctly identified to the species/complex/group level; 7 (9.6%) resulted in no identification; and 2 (2.7%) were misidentified at the species level. These results indicate that the Vitek MS v3.0 system is an accurate tool for routine diagnostics of Mycobacterium species isolated from liquid cultures.<br /> (Copyright © 2018 American Society for Microbiology.)

Details

Language :
English
ISSN :
1098-660X
Volume :
56
Issue :
8
Database :
MEDLINE
Journal :
Journal of clinical microbiology
Publication Type :
Academic Journal
Accession number :
29875193
Full Text :
https://doi.org/10.1128/JCM.00219-18