Concentrations of polychlorinated biphenyls in soil and indoor dust associated with electricity generation facilities in Lagos, Nigeria.

Authors :
Folarin BT
Abdallah MA
Oluseyi T
Olayinka K
Harrad S
Source :
Chemosphere [Chemosphere] 2018 Sep; Vol. 207, pp. 620-625. Date of Electronic Publication: 2018 May 19.
Publication Year :
2018

Abstract

Concentrations of 7 indicator polychlorinated biphenyls (PCBs) were measured in dust and soil samples from 12 power stations collected over the two major seasons of the Nigerian climate. Median ƩPCB <subscript>7</subscript> concentrations in soil ranged from 2 ng/g for power station A to 220 ng/g for power station I; while those in dust ranged from 21 ng/g for power station L to 2200 ng/g for power station I. For individual congeners, median PCB concentrations ranged from 3.8 ng/g for PCB 101 to 52 ng/g for PCB 180 in dust, and <0.07 ng/g for PCB 28 to 5.9 ng/g for PCB 153 in soil. The type of power station activity exerted a significant influence on concentrations of ΣPCB <subscript>7</subscript> in dust and soil (generation > transmission > distribution). Congener patterns in dust and soil samples were compared using principal component analysis (PCA) with those in transformer oil samples from 3 of the power stations studied and with common PCB mixtures (Aroclors). This revealed congener patterns in soil were more closely related to that in the transformer oil than dust. Congener patterns in most samples were similar to Aroclor 1260. Concentrations of PCBs in soil samples close to the transformers significantly exceeded those in soil sampled further away.<br /> (Copyright © 2018 Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1879-1298
Volume :
207
Database :
MEDLINE
Journal :
Chemosphere
Publication Type :
Academic Journal
Accession number :
29852461
Full Text :
https://doi.org/10.1016/j.chemosphere.2018.05.110