Back to Search Start Over

Real-time shear wave elastography (SWE) assessment of short- and long-term treatment outcome in Budd-Chiari syndrome: A pilot study.

Authors :
Wang HW
Shi HN
Cheng J
Xie F
Luo YK
Tang J
Source :
PloS one [PLoS One] 2018 May 30; Vol. 13 (5), pp. e0197550. Date of Electronic Publication: 2018 May 30 (Print Publication: 2018).
Publication Year :
2018

Abstract

Purpose: The first aim of this study was to analyze the relationships between liver stiffness measurement, hepatic venous pressure and liver fibrosis. The second aim was to demonstrate the utility of real-time shear wave elastography for evaluation of Budd-Chiari syndrome patients before and after balloon hepatic venous angioplasty.<br />Materials and Methods: A total of 32 patients with Budd-Chiari syndrome slated for successful balloon angioplasty met the inclusion and exclusion criteria. Shear wave elastography was used to generate dynamic liver stiffness measurement 2 days before angioplasty and 2 days, 3 months, and 6 months after angioplasty. Hepatic venous pressures were measured during balloon angioplasty. Correlations among liver stiffness, hepatic venous pressure, and fibrosis were assessed.<br />Result: Mean liver stiffness was 35.17 ± 10.60 kPa, 20.15 ± 5.47 kPa, 15.36 ± 4.34 kPa and 15.68 ± 5.58 kPa at baseline and 2 days, 3 months, and 6 months after angioplasty, respectively. Liver stiffness measured at 2 days and 3 months after angioplasty was significantly decreased (P < 0.001); liver stiffness measured at 6 months after angioplasty was not significantly different from that measured at 3 months after angioplasty (P = 0.636). Analysis of liver stiffness measurement and hepatic venous pressure before balloon angioplasty yielded a coefficient of correlation r = 0.701 (P < 0.001). Before and 2d after angioplasty, liver stiffness measurement did not correlated with fibrosis (r = - 0.170, P = 0.22), (r = 0.223, P = 0.220), respectively, while the LSM difference before and 2 days after angioplasty negatively correlated with stiffness severity (r = - 0.502, P = 0.003). Liver stiffness measured at 2 days and 3 months after angioplasty was significantly decreased (P < 0.001), remaining stable at 3 months, though still in the cirrhotic range.<br />Conclusions: The liver stiffness of Budd-Chiari syndrome patients, measured by shear wave elastography, decreased considerably after hepatic venous recanalization, and significantly correlated with hepatic venous pressure though not with degree of fibrosis. Shear wave elastography may be effective in monitoring short- and long-term treatment outcomes in Budd-Chiari syndrome.<br />Competing Interests: The authors have declared that no competing interests exist.

Details

Language :
English
ISSN :
1932-6203
Volume :
13
Issue :
5
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
29847588
Full Text :
https://doi.org/10.1371/journal.pone.0197550