Back to Search Start Over

Ultra-trace Cu isotope ratio measurements via multi-collector ICP-mass spectrometry using Ga as internal standard: an approach applicable to micro-samples.

Authors :
Lauwens S
Costas-Rodríguez M
Vanhaecke F
Source :
Analytica chimica acta [Anal Chim Acta] 2018 Sep 26; Vol. 1025, pp. 69-79. Date of Electronic Publication: 2018 May 09.
Publication Year :
2018

Abstract

The capabilities of Cu isotope ratio measurements are often restricted by the small volumes of sample available and/or their low Cu concentration. In this work, an analytical approach was developed for performing Cu isotopic analysis via multi-collector ICP-mass spectrometry (MC-ICP-MS) at ultra-trace level using Ga as an internal standard for mass bias correction. The minimum concentration of Cu required for accurate and precise isotope ratio measurements was established to be 20 μg L <superscript>-1</superscript> with wet plasma conditions and 5 μg L <superscript>-1</superscript> with dry plasma conditions. The use of Ga as an internal standard for mass bias correction provided several advantages compared to Ni, i.e. improved internal precision on δ <superscript>65</superscript> Cu values and lower blank levels. Ga can also be used at a 4-fold lower concentration level than Ni. However, in wet plasma conditions, the signals of <superscript>36</superscript> Ar <superscript>16</superscript> O <subscript>2</subscript> <superscript>1</superscript> H <superscript>+</superscript> and <superscript>40</superscript> Ar <superscript>15</superscript> N <superscript>16</superscript> O <superscript>+</superscript> interfered with the signals of <superscript>69</superscript> Ga <superscript>+</superscript> and <superscript>71</superscript> Ga <superscript>+</superscript> , respectively, while in dry plasma conditions, realized by the use of a desolvation unit, <superscript>69</superscript> Ga <superscript>+</superscript> suffered from spectral interference from <superscript>40</superscript> Ar <superscript>14</superscript> N <subscript>2</subscript> <superscript>1</superscript> H <superscript>+</superscript> . These interferences were resolved by using medium mass resolution. For validation purposes, the approach was applied to commercially available blood and serum samples. The δ <superscript>65</superscript> Cu values for the samples measured at a concentration level of 5 μg L <superscript>-1</superscript> Cu and 5 μg L <superscript>-1</superscript> Ga using dry plasma conditions were in good agreement with those obtained for isotope ratio measurements at the "standard" concentration level of 200 μg L <superscript>-1</superscript> Cu and 200 μg L <superscript>-1</superscript> Ni using wet plasma conditions. In addition, the δ <superscript>65</superscript> Cu values obtained for micro-samples of serum/blood (volume of 100 µL) were in good agreement with the corresponding ones obtained using the "standard" volume for isotopic analysis (500 μL).<br /> (Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-4324
Volume :
1025
Database :
MEDLINE
Journal :
Analytica chimica acta
Publication Type :
Academic Journal
Accession number :
29801609
Full Text :
https://doi.org/10.1016/j.aca.2018.05.025