Back to Search Start Over

[Arthroscopic treatment of both anterior and posterior cruciate ligament tibial insertion avulsion fractures with suture and absorbable screw double fixation].

Authors :
Zhao D
Li Y
Jiang Z
Li Y
Zhang J
Wu Z
Wang F
Wang G
He C
Source :
Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery [Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi] 2016 Jul 08; Vol. 30 (7), pp. 822-825.
Publication Year :
2016

Abstract

Objective: ?To evaluate the effectiveness of arthroscopic suture and absorbable screw double fixation for both anterior and posterior cruciate ligament avulsion fractures of tibial insertions.<br />Methods: ?Between June 2006 and September 2013, 8 patients with anterior and posterior cruciate ligament avulsion fractures of the tibial eminence underwent arthroscopic treatment with suture and absorbable screw double fixation. There were 5 males and 3 females, with a mean age of 28.9 years (range, 18-43 years). The causes of injury included traffic accident in 5 cases and falling from height in 3 cases. The time from injury to operation was 3-10 days (mean, 6.2 days). The Lysholm knee score, International Knee Documentation Committee (IKDC) score, and Tegner rating scales were used to evaluated the knee function.<br />Results: ?Primary healing of incision was obtained, without infection or deep vein thrombosis. The mean follow-up period was 42.4 months (range, 24 to 65 months). At 3 months after operation, X-ray films showed good reduction and healing of fracture. The anterior and posterior drawer tests were negative. The knee range of motion was normal (0-125°), and it recovered to preoperative level in 7 cases. The IKDC score, Tegner score, and Lysholm score were significantly improved to 90.4±5.2, 7.5±1.6, and 89.2±3.5 from preoperative 52.1±3.3, 3.3±1.0, and 51.9±3.5 respectively (t=-38.680, P=0.000; t=-39.520, P=0.000; t=-41.150, P=0.000).<br />Conclusions: ?A combined injury of anterior and posterior cruciate ligament avulsion fractures of tibial insertions is rare. Arthroscopic treatment with suture and absorbable screw double fixation is a useful technique to restore tibial avulsion injuries with well-documented radiographic healing, good clinical outcomes, and low complication rates.

Details

Language :
Chinese
ISSN :
1002-1892
Volume :
30
Issue :
7
Database :
MEDLINE
Journal :
Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery
Publication Type :
Academic Journal
Accession number :
29786316
Full Text :
https://doi.org/10.7507/1002-1892.20160168