Back to Search Start Over

Quality Control of Next-generation Sequencing-based In vitro Diagnostic Test for Onco-relevant Mutations Using Multiplex Reference Materials in Plasma.

Authors :
Liu D
Zhou H
Shi D
Shen S
Tian Y
Wang L
Lou J
Cong R
Lu J
Zhang H
Zhao M
Zhu S
Cao Z
Jin R
Wang Y
Zhang X
Yang G
Wang Y
Zhang C
Source :
Journal of Cancer [J Cancer] 2018 Apr 18; Vol. 9 (9), pp. 1680-1688. Date of Electronic Publication: 2018 Apr 18 (Print Publication: 2018).
Publication Year :
2018

Abstract

Background: Widespread clinical implementation of next-generation sequencing (NGS)-based cancer in vitro diagnostic tests (IVDs) highlighted the urgency to establish reference materials which could provide full control of the process from nucleic acid extraction to test report generation. The formalin-fixed, paraffin-embedded (FFPE) tissue and blood plasma containing circulating tumor deoxyribonucleic acid (ctDNA) were mostly used for clinically detecting onco-relevant mutations. Methods: We respectively developed multiplex FFPE and plasma reference materials covering three clinically onco-relevant mutations within the epidermal growth factor receptor ( EGFR ) gene at serial allelic frequencies. All reference materials were quantified and validated via droplet digital polymerase chain reaction (ddPCR), and then were distributed to eight domestic manufacturers for the collaborative evaluation of the performance of several domestic NGS-based cancer IVDs covering four major NGS platforms (NextSeq, HiSeq, Ion Proton and BGISEQ). Results: All expected mutations except one at extremely low allelic frequencies were detected, despite some differences in coefficient of variation (CV) which increased with the decrease of allelic frequency (CVs ranging from 18% to 106%). It was worth noting that the CV value seemed to correlate with a particular mutation as well. The repeatability of determination of different mutations was L858R>T790M>19del. Conclusions: The results indicated our reference materials would be pivotal for quality control of NGS-based cancer IVDs and would guide the further development of reference materials covering more onco-relevant mutations.<br />Competing Interests: Competing Interests: The authors have declared that no competing interest exists.

Details

Language :
English
ISSN :
1837-9664
Volume :
9
Issue :
9
Database :
MEDLINE
Journal :
Journal of Cancer
Publication Type :
Academic Journal
Accession number :
29760807
Full Text :
https://doi.org/10.7150/jca.24126