Back to Search Start Over

Tomosynthesis implementation with adaptive online calibration on clinical C-arm systems.

Authors :
Chung K
Schad LR
Zöllner FG
Source :
International journal of computer assisted radiology and surgery [Int J Comput Assist Radiol Surg] 2018 Oct; Vol. 13 (10), pp. 1481-1495. Date of Electronic Publication: 2018 May 08.
Publication Year :
2018

Abstract

Purpose: Cone beam computed tomography (CBCT) systems offer physicians crucial 3D and 2D imaging capabilities during interventions. However, certain medical applications only require very specific information from the CBCTs (e.g., determination of the position of high-contrast objects). In diagnostics, tomosynthesis techniques can be used in these cases to minimize dose exposure. Therefore, integrating such techniques on CBCT systems could also be beneficial for interventions. In this paper, we investigate the performance of our implementation of circular tomosynthesis on a CBCT device.<br />Methods: The tomosynthesis scan trajectory is realized with step-and-shoot on a clinical C-arm device. The online calibration algorithm uses conventionally acquired 3D CBCT of the scanned object as prior knowledge to correct the imaging geometries. The online calibration algorithm was compared to an offline calibration to test its performance. A ball bearing phantom was used to evaluate the reconstructions with respect to geometric distortions. The evaluation was done for three different scenarios to test the robustness of our tomosynthesis implementation against object deviations (e.g., pen) and different object positioning.<br />Results: The circular tomosynthesis was tested on a ball bearing and an anthropomorphic phantom. The results show that the calibration is robust against isocenter shifts and object deviations in the CBCT. All reconstructions used 100 projections and displayed limited angle artifacts. The accuracy of the positions and shapes of high-contrast objects were, however, determined precisely. (The maximal center position deviation is 0.31 mm.) CONCLUSION: For medical procedures that primarily determine the precise position of high-contrast objects, circular tomosynthesis could offer an approach to reduce dose exposure.

Details

Language :
English
ISSN :
1861-6429
Volume :
13
Issue :
10
Database :
MEDLINE
Journal :
International journal of computer assisted radiology and surgery
Publication Type :
Academic Journal
Accession number :
29740752
Full Text :
https://doi.org/10.1007/s11548-018-1782-y