Back to Search Start Over

The development of central venous thrombosis in hemodialyzed patients is associated with catheter tip depth and localization.

Authors :
Premuzic V
Perkov D
Smiljanic R
Source :
Hemodialysis international. International Symposium on Home Hemodialysis [Hemodial Int] 2018 Oct; Vol. 22 (4), pp. 454-462. Date of Electronic Publication: 2018 May 02.
Publication Year :
2018

Abstract

Introduction: The aim of our work was to analyze the incidence of tunneled hemodialysis catheters-related thrombosis in hemodialyzed patients depending on catheter tip depth and position and to evaluate the impact of other established risk factors responsible for development of central venous thrombosis.<br />Methods: The presence of central vein thrombosis, location, and the depth of the catheter tip was reviewed by two experienced radiologists. All patients with suspected central venous thrombosis had factor V Leiden, lupus anticoagulant, and cardiolipin antibodies checked (acIgM and acIgG) and were evaluated with cat-scan venography.<br />Findings: A total of 68 tunneled hemodialysis catheters were analyzed with CT venography for central venous thrombosis. There were no signs of central venous thrombosis when catheter tips were placed in the right atrium. There was significantly higher number of catheter tips located on the vein wall than located centrally in patients with central venous thrombosis. Higher percentage of central venous thrombosis, smaller number of tips placed in the right atrium, higher values of IgM cardiolipin antibodies, and higher number of patients with positive factor V Leiden mutation were found in group of patients with catheter tips located on vein wall.<br />Discussion: Higher incidence of central venous thrombosis in patients with the catheter tip placed on the vein wall is a consequence of a catheter tip depth proximal of the right atrium. Increased factor V Leiden mutation and acIgM values in these patients should be observed as a result of the vein stasis caused by inappropriate catheter tip depth and localization.<br /> (© 2018 International Society for Hemodialysis.)

Details

Language :
English
ISSN :
1542-4758
Volume :
22
Issue :
4
Database :
MEDLINE
Journal :
Hemodialysis international. International Symposium on Home Hemodialysis
Publication Type :
Academic Journal
Accession number :
29722112
Full Text :
https://doi.org/10.1111/hdi.12662