Back to Search Start Over

[Coil Embolization for Very Small Intracranial Aneurysms with Diameter Less than 3mm:A Case Series of 14 Patients and Literature Review].

Authors :
Maeda K
Motoie R
Karashima S
Otsuji R
Ren N
Nagaoka S
Ikai Y
Uno J
Gi H
Source :
No shinkei geka. Neurological surgery [No Shinkei Geka] 2018 Apr; Vol. 46 (4), pp. 303-312.
Publication Year :
2018

Abstract

Introduction: Many studies describe aneurysms measuring ≤3mm as "very small" or "tiny, " with a risk of intraoperative rupture higher than that of most cerebral aneurysms. We evaluated the results of endovascular coil embolization for very small aneurysms with diameter ≤3mm.<br />Material and Methods: The same interventional neurosurgeon performed coil embolization for 14 tiny aneurysms in 14 patients(8male and 6 females)at our institution between May 2015 and June 2017. Patient age range was 42-88 years(average 65.6 years). Five aneurysms had ruptured and 9 were unruptured. Of the 9 unruptured aneurysms, 3 were associated with a previous ruptured aneurysm. We assessed the procedural complications, type of microcatheter and coils used, total number and length of coils, and angiographic results immediately after the procedure.<br />Results: In 14 aneurysm cases, 8 used only 1 pre-shaped microcatheter, 4 used 2, and 2 used 3;cases using multiple microcatheters added final shaping. Only one case used a helical first coil and the remaining 13 cases used a 3-dimensional coil. The number of coils used was 1 in 3 cases, 2 in 7 cases, 3 in 2 cases, and 4 in 2 cases. The total length of coils inserted was <5 cm in 5 cases, 5-10 cm in 5 cases, and >10 cm in 4 cases. The total length of coils used was <10cm in 70% of cases. Immediately after coil embolization, complete occlusion and a neck remnant were achieved in 11 and 3 cases, respectively. Ballooning was induced by intentionally introducing a balloon-assist technique during surgery in 7 cases, and the balloon was actually inflated in 4 cases. Complications were seen in 2 ruptured cases;1 had an intraoperative rupture, the other had parent artery occlusion, and both patients recovered.<br />Conclusion: Coil embolization for tiny aneurysms can be performed comparatively safely by understanding the pitfalls and by using appropriate procedures and tools. Placing the catheter tip at the aneurysm neck is the first step and endovascular treatment is usually performed with ≤3 coils measuring ≤10 cm in total length. Complete embolization should be attempted, but even incomplete embolization is acceptable. More delicate coil embolization is required.

Details

Language :
Japanese
ISSN :
0301-2603
Volume :
46
Issue :
4
Database :
MEDLINE
Journal :
No shinkei geka. Neurological surgery
Publication Type :
Academic Journal
Accession number :
29686163
Full Text :
https://doi.org/10.11477/mf.1436203721