Back to Search
Start Over
Impact of Balloon Predilatation on Hemodynamics and Outcomes After Transcatheter Aortic Valve Implantation With the Self-Expanding CoreValve Prosthesis.
- Source :
-
The American journal of cardiology [Am J Cardiol] 2018 Jun 01; Vol. 121 (11), pp. 1358-1364. Date of Electronic Publication: 2018 Mar 01. - Publication Year :
- 2018
-
Abstract
- The impact of predilatation (Pre-Dil) on prosthesis hemodynamics and clinical outcomes of subjects who underwent transcatheter aortic valve implantation (TAVI) with a self-expanding prosthesis remains unclear. Two thousand seven hundred twenty-one subjects from the extreme- and high-risk CoreValve Continued Access Study (CAS) were included in the analysis. Subjects who underwent Pre-Dil before TAVI were compared with subjects who underwent TAVI without Pre-Dil. Clinical outcomes included death, stroke, myocardial infarction, acute kidney injury, and new permanent pacemaker implantation. Serial echocardiograms were analyzed to evaluate prosthesis hemodynamics, specifically paravalvular regurgitation, effective orifice area, and mean gradient. Two thousand one hundred eighteen and 603 subjects underwent TAVI with and without Pre-Dil, respectively. Subjects in the Pre-Dil cohort were more commonly male, while subjects in the no Pre-Dil cohort had higher rates of previous stroke and lower mean aortic valve gradients. Outcomes at 30 days were comparable between Pre-Dil and no Pre-Dil subjects, with no significant difference in mortality (5.5% vs 4.3%, p = 0.27), major stroke (2.6% vs 2.2%, p = 0.54), major vascular complications (6.9% vs 8.0%, p = 0.37), major bleeding (24.4% vs 26.1%, p = 0.40), and permanent pacemaker implantation (21.3% vs 23.4%, p = 0.36). There were no significant differences in the same outcomes at 12 months. Effective orifice area and mean gradient were comparable between Pre-Dil and no-Pre-Dil subjects at discharge, at 30 days, and at 12 months. In conclusion, when performing TAVI with the self-expanding CoreValve device, performing direct implantation without Pre-Dil maintains an acceptable safety profile and still achieves desired and consistent prosthesis hemodynamics.<br /> (Copyright © 2018 Elsevier Inc. All rights reserved.)
- Subjects :
- Acute Kidney Injury epidemiology
Aged
Aged, 80 and over
Bundle-Branch Block epidemiology
Bundle-Branch Block therapy
Cardiac Pacing, Artificial
Echocardiography
Female
Hemodynamics
Humans
Male
Mortality
Myocardial Infarction epidemiology
Pacemaker, Artificial
Severity of Illness Index
Stroke epidemiology
Treatment Outcome
Aortic Valve Stenosis surgery
Dilatation methods
Heart Valve Prosthesis
Transcatheter Aortic Valve Replacement methods
Subjects
Details
- Language :
- English
- ISSN :
- 1879-1913
- Volume :
- 121
- Issue :
- 11
- Database :
- MEDLINE
- Journal :
- The American journal of cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 29680171
- Full Text :
- https://doi.org/10.1016/j.amjcard.2018.02.008