Back to Search Start Over

Impact of an additional right pulmonary vein on second-generation cryoballoon ablation for atrial fibrillation: a propensity matched score study.

Authors :
Takarada K
Ströker E
Abugattas JP
de Regibus V
Coutiño HE
Lusoc I
Capulzini L
Sieira J
Mugnai G
Salghetti F
Choudhury R
Iacopino S
de Asmundis C
Brugada P
Chierchia GB
Source :
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing [J Interv Card Electrophysiol] 2019 Jan; Vol. 54 (1), pp. 1-8. Date of Electronic Publication: 2018 Apr 21.
Publication Year :
2019

Abstract

Purpose: Cryoballoon (CB) technology in the context of anatomical pulmonary vein (PV) variants might hypothetically hamper successful PV isolation (PVI). Our aim was to assess the impact of a right middle PV (RMPV) in the setting of second-generation cryoballoon (CB advance-CB-A), on procedural parameters and on mid-term follow-up.<br />Methods: Consecutive patients with AF presenting RMPV (RMPV+) at the pre-procedural computed tomography who underwent PVI by CB-A were enrolled. Comparison with propensity score-matched patients without RMPV (RMPV-) was performed. Acute procedural parameters and clinical follow-up were assessed.<br />Results: A total of 240 patients (80 RMPV+) were included in the analysis. Twelve of 80 (15%) RMPV+ patients underwent a direct cryo-application in this variant and accomplished the isolation without phrenic nerve palsy, whereas in 25 of 80 (31%) RMPV+ patients, the RMPVs were not targeted directly nor indirectly (by co-occlusion during application at a major PV). At a median follow-up of 17.3 [interquartile range 11.3-26.5] months, there was no significant difference in AF-free survival between RMPV+ and RMPV- patients (78.8 vs 78.1%, P = 1.00), and the recurrence of atrial arrhythmias among patients with versus without an intentional or indirect cryo-application to the RMPV was not different (22 vs 20%, P = 1.00).<br />Conclusions: Mid-term outcome after CB-A ablation did not differ between RMPV+ and RMPV- patients. Within RMPV+ patients, outcome was similar between those with versus without a cryo-application (either direct or indirect) to the additional vein.

Details

Language :
English
ISSN :
1572-8595
Volume :
54
Issue :
1
Database :
MEDLINE
Journal :
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing
Publication Type :
Academic Journal
Accession number :
29679186
Full Text :
https://doi.org/10.1007/s10840-018-0373-8