Back to Search
Start Over
[Evaluation of the coagulometer STA R Max ® (Stago) for routine coagulation parameters].
- Source :
-
Annales de biologie clinique [Ann Biol Clin (Paris)] 2018 Apr 01; Vol. 76 (2), pp. 143-149. - Publication Year :
- 2018
-
Abstract
- The STA R Max <superscript>®</superscript> is a fully automated multiparameter coagulometer using clotting (viscosity-based detection system), chromogenic and immunologic assays. STA R Max <superscript>®</superscript> is equipped with an innovative software (STA Coag Expert <superscript>®</superscript> ) designed to assist laboratory in accreditation. The aim of this study was to evaluate its performances for the certification according to ISO 15189 quality standard in the haemostasis unit of our university hospital. The following tests were evaluated: prothrombin time (PT), activated partial thromboplastin time (aPTT), kaolin cephalin clotting time (KCCT), fibrinogen, anti-Xa assay and D-dimers. In normal and pathological range, the intra-assay coefficients of variation (CV) for PT, aPTT, KCCT and fibrinogen were below 4.0%. Intra-assay CV was of 4.0% for the anti-Xa assay and intra-assay CV was of 7.9% for D-dimers. Inter-assay CV were below 5.0% for PT, aPPT, KCCT and fibrinogen, 14.9% for anti-Xa assay and 8.6% for D-dimers. The interlaboratory comparisons were below 8.7% for PT, aPPT and KCCT, 5.0% for fibrinogen and 15.5% for anti-Xa assay. All results were acceptable according to suitable CV established by GFHT and the provider. The concordance between all coagulometers was excellent, with correlation coefficient close to 1 (0.99 for all parameters except for aPPT which was 0.98) calculated thanks to an intra-class correlation study. In conclusion, the STA R Max <superscript>®</superscript> analyser is suitable for haemostasis laboratories and facilitates certification of a laboratory.
- Subjects :
- Automation, Laboratory
Diagnostic Tests, Routine instrumentation
Diagnostic Tests, Routine methods
France
Hematology instrumentation
Hematology methods
Humans
Reproducibility of Results
Sensitivity and Specificity
Software
Blood Coagulation physiology
Blood Coagulation Tests instrumentation
Blood Coagulation Tests methods
Subjects
Details
- Language :
- French
- ISSN :
- 1950-6112
- Volume :
- 76
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Annales de biologie clinique
- Publication Type :
- Academic Journal
- Accession number :
- 29623883
- Full Text :
- https://doi.org/10.1684/abc.2018.1333