Back to Search
Start Over
Implementation of Size-Dependent Local Diagnostic Reference Levels for CT Angiography.
- Source :
-
AJR. American journal of roentgenology [AJR Am J Roentgenol] 2018 May; Vol. 210 (5), pp. W226-W233. Date of Electronic Publication: 2018 Mar 23. - Publication Year :
- 2018
-
Abstract
- Objective: Diagnostic reference levels (DRLs) are established for standard-sized patients; however, patient dose in CT depends on patient size. The purpose of this study was to introduce a method for setting size-dependent local diagnostic reference levels (LDRLs) and to evaluate these LDRLs in comparison with size-independent LDRLs and with respect to image quality.<br />Materials and Methods: One hundred eighty-four aortic CT angiography (CTA) examinations performed on either a second-generation or third-generation dual-source CT scanner were included; we refer to the second-generation dual-source CT scanner as "CT1" and the third-generation dual-source CT scanner as "CT2." The volume CT dose index (CTDI <subscript>vol</subscript> ) and patient diameter (i.e., the water-equivalent diameter) were retrieved by dose-monitoring software. Size-dependent DRLs based on a linear regression of the CTDI <subscript>vol</subscript> versus patient size were set by scanner type. Size-independent DRLs were set by the 5th and 95th percentiles of the CTDI <subscript>vol</subscript> values. Objective image quality was assessed using the signal-to-noise ratio (SNR), and subjective image quality was assessed using a 4-point Likert scale.<br />Results: The CTDI <subscript>vol</subscript> depended on patient size and scanner type (R <superscript>2</superscript> = 0.72 and 0.78, respectively; slope = 0.05 and 0.02 mGy/mm; p < 0.001). Of the outliers identified by size-independent DRLs, 30% (CT1) and 67% (CT2) were adequately dosed when considering patient size. Alternatively, 30% (CT1) and 70% (CT2) of the outliers found with size-dependent DRLs were not identified using size-independent DRLs. A negative correlation was found between SNR and CTDI <subscript>vol</subscript> (R <superscript>2</superscript> = 0.36 for CT1 and 0.45 for CT2). However, all outliers had a subjective image quality score of sufficient or better.<br />Conclusion: We introduce a method for setting size-dependent LDRLs in CTA. Size-dependent LDRLs are relevant for assessing the appropriateness of the radiation dose for an individual patient on a specific CT scanner.
Details
- Language :
- English
- ISSN :
- 1546-3141
- Volume :
- 210
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- AJR. American journal of roentgenology
- Publication Type :
- Academic Journal
- Accession number :
- 29570369
- Full Text :
- https://doi.org/10.2214/AJR.17.18566