Titanium TSME appliance for patients allergic to nickel.

Authors :
Maspero C
Galbiati G
Giannini L
Guenza G
Esposito L
Farronato G
Source :
European journal of paediatric dentistry [Eur J Paediatr Dent] 2018 Mar; Vol. 19 (1), pp. 67-69.
Publication Year :
2018

Abstract

Aim: The aim of this article is to describe the use of a titanium TSME appliance for patients with allergy to resin and nickel. We aim to highlight the optimal way to avoid problems such as stomatitis and peri-labial dermatitis, which generally appear in patients who use traditional orthodontic appliances made in acrylic resin and steel.<br />Materials and Methods: The construction of a titanium appliance is described and a case treated with it is reported.<br />Results: The titanium TSME presented in this paper has excellent biocompatibility due to its ability to form superficial oxides, which prevent oxidation and thus corrosion.<br />Conclusion: The non-allergic properties of titanium allow to propose it as an alternative in patients with a long-term history of allergic reactions to nichel.