Back to Search Start Over

Quantitative MDCT assessment of binder effects after pelvic ring disruptions using segmented pelvic haematoma volumes and multiplanar caliper measurements.

Authors :
Dreizin D
Bodanapally U
Mascarenhas D
O'Toole RV
Tirada N
Issa G
Nascone J
Source :
European radiology [Eur Radiol] 2018 Sep; Vol. 28 (9), pp. 3953-3962. Date of Electronic Publication: 2018 Mar 13.
Publication Year :
2018

Abstract

Objective: To assess effects of pelvic binders for different instability grades using quantitative multidetector computed tomography (MDCT) parameters including segmented pelvic haematoma volumes and multiplanar caliper measurements.<br />Methods: CT examinations of 49 patients with binders and 49 controls performed from January 2008-June 2016, and matched 1:1 for Tile instability grade and Pennal/Young-Burgess force vector, were compared for differences in pubic symphysis and sacroiliac displacement using caliper measurements in three orthogonal planes. Pelvic haematoma volumes (ml) were derived using semi-automated seeded region-growing segmentation. Median caliper measurements and volumes were compared using the Mann-Whitney U test, and correlations assessed with Pearson's correlation coefficient. Relevant caliper measurement cutoffs were established using ROC analysis.<br />Results: Rotationally unstable (Tile B) patients with binders showed significant decreases in sacroiliac diastasis (2.7 mm vs. 4.5 mm; p=0.003) and haematoma volumes (135 ml vs. 295 ml; p=0.008). Globally unstable (Tile C) binder patients showed decreased sacroiliac diastasis (4.7 mm vs. 6.4 mm, p=0.04), without significant difference in haematoma volumes (284 ml vs. 234 ml, p=0.34). Four Tile C patients with binders demonstrated over-reduction resulting in pubic body over-ride.<br />Conclusion: Rotationally unstable patients with binders have significantly less sacroiliac diastasis versus controls, corresponding with significantly lower haematoma volumes.<br />Key Points: • Haematoma segmentation and multiplanar caliper measurements provide new insights into binder effects. • Binder reduction corresponds with decreased pelvic haematoma volume in rotationally unstable injuries. • Discrimination between rotational and global instability is important for management. • Several caliper measurement cut-offs discriminate between rotationally and globally unstable injuries. • Pubic symphysis over-ride is suggestive of binder over-reduction in globally unstable injuries.

Details

Language :
English
ISSN :
1432-1084
Volume :
28
Issue :
9
Database :
MEDLINE
Journal :
European radiology
Publication Type :
Academic Journal
Accession number :
29536245
Full Text :
https://doi.org/10.1007/s00330-018-5303-8