Background: In all, there have been 178 variant Creutzfeldt-Jakob disease (vCJD) patients diagnosed in the UK, with an estimated maximum 1:2000 carriage rate based on archived appendix and tonsil tissue, implying that infection may be rare but carriage relatively frequent. Previous workers have identified that maintenance of surgical instruments in a humid atmosphere after use and prior to cleaning assists cleaning efficacy. Recently the Department of Health/Advisory Committee on Dangerous Pathogens UK have recommended a surgical instrument cleanliness threshold post cleaning of <5 μg protein per instrument side.<br />Aim: To quantify cleanliness of neurosurgical instruments and to investigate cost-effective measures for improved cleaning.<br />Methods: Two instrument protein quantification methods were used: one based on the International Standard (15883 series) using sodium dodecyl sulphate elution and ortho-phthalaldehyde reaction, and a second in-situ protein fluorescence detection system (ProReveal) providing results per instrument side. In-vitro investigation of the efficacy of some commercial and in-house pre-clean wetting agents was undertaken using artificial test soil and stainless steel discs under standard conditions. In-vivo evaluation of best-performing in-vitro agents was undertaken on craniotomy sets.<br />Findings: ProReveal technology demonstrated that 163 out of 187 (87%) neurosurgical instruments had <5 μg residual protein per instrument side. The use of proprietary National Health Service plastic bags and sterile water-soaked wound pads were equivalent in efficacy to commercial pre-cleaning wetting products and significantly less expensive.<br />Conclusion: Although we demonstrate low in-situ protein levels on neurosurgical instruments and the beneficial effects of keeping instruments moist, other cleaning critical-control points such as instrument loading patterns should also be monitored.<br /> (Copyright © 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1532-2939
Volume :
100
Issue :
3
Database :
MEDLINE
Journal :
The Journal of hospital infection
Publication Type :
Academic Journal
Accession number :
29530742
Full Text :
https://doi.org/10.1016/j.jhin.2018.03.001