An Alternative Approach for Treating a Type Ia Endoleak after Conventional EVAR Using the Nellix Endovascular Aneurysm Sealing.
- Source :
-
Annals of vascular surgery [Ann Vasc Surg] 2018 May; Vol. 49, pp. 316.e5-316.e10. Date of Electronic Publication: 2018 Mar 01. - Publication Year :
- 2018
-
Abstract
- Background: To report the use of a Nellix endovascular aneurysm sealing (EVAS) device, to successfully treat a type Ia endoleak (EL) after an endovascular aortic repair (EVAR).<br />Case Report: A 70-year-old man was diagnosed with a 90-mm aortic aneurysm, suspicious for being inflammatory. It was initially treated successfully, with a Medtronic Endurant (Medtronic, Minneapolis, MN, USA). Five years after the index endovascular repair, an asymptomatic type Ia EL was detected on duplex ultrasound and computed tomographic angiogram. Other endovascular solutions in the form of proximal cuff, chimney was considered difficult to execute due to challenges in planning, manipulation, and renal cannulation caused by the short proximal sealing zone above the existing stent graft and the constraints of the previous endograft. Thus, a relining of the previous endoprothesis was performed using the Nellix system (Endologix, Inc., Irvine, CA, USA). One-year follow-up imaging demonstrated successful resolution of the EL and persistent sealing of the Nellix device.<br />Conclusions: Nellix EVAS system can be an alternative and safe option for relining a stent graft with a type Ia EL. Nellix platform can be added to the clinician's armamentarium for treating type Ia EL after conventional EVAR of infrarenal abdominal aortic aneurysm (AAA).<br /> (Copyright © 2018 Elsevier Inc. All rights reserved.)
- Subjects :
- Aged
Aortic Aneurysm, Abdominal diagnostic imaging
Aortography methods
Blood Vessel Prosthesis Implantation adverse effects
Computed Tomography Angiography
Endoleak diagnostic imaging
Endoleak etiology
Endovascular Procedures adverse effects
Humans
Male
Prosthesis Design
Treatment Outcome
Ultrasonography, Doppler, Duplex
Aortic Aneurysm, Abdominal surgery
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation instrumentation
Endoleak surgery
Endovascular Procedures instrumentation
Stents
Subjects
Details
- Language :
- English
- ISSN :
- 1615-5947
- Volume :
- 49
- Database :
- MEDLINE
- Journal :
- Annals of vascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 29501907