Distribution and Detection of Radiopaque Beads after Hepatic Transarterial Embolization in Swine: Cone-Beam CT versus MicroCT.

Authors :
Thompson JG
van der Sterren W
Bakhutashvili I
van der Bom IM
Radaelli AG
Karanian JW
Esparza-Trujillo J
Woods DL
Lewis AL
Wood BJ
Pritchard WF
Source :
Journal of vascular and interventional radiology : JVIR [J Vasc Interv Radiol] 2018 Apr; Vol. 29 (4), pp. 568-574. Date of Electronic Publication: 2018 Mar 02.
Publication Year :
2018

Abstract

Purpose: To determine the true distribution of radiopaque beads (ROBs) after hepatic embolization in swine as imaged by micro-computed tomography (microCT) compared with in vivo cone-beam computerized tomography (CT) imaged at different kVp settings.<br />Materials and Methods: Swine (n = 3) underwent hepatic transarterial embolization (n = 6) with the use of 70-150-μm ROBs under fluoroscopic guidance. After stasis, in vivo cone-beam CT was performed at 120, 100, and 80 kVp. The animal was euthanized, the liver resected, and microCT with 17 μm resolution performed on embolized tissue samples. The resulting cone-beam CT and microCT data were segmented and registered. Total vessel length, minimum volume-enclosing ellipsoid (MVEE), and number of independent volumes were measured. Maximum-intensity projections (MIPs) were generated for each cone-beam CT.<br />Results: Metrics for all cone-beam CT segmentations differed significantly from microCT segmentations. Segmentations at 80 kVp presented significantly greater vessel length, MVEE, and number of independent volumes compared with 100 kVp and 120 kVp. In addition, 100 kVp segmentations presented significantly greater vessel length than 120 kVp. MIPs presented greater visualization than cone-beam CT segmentations and improved as kVp decreased.<br />Conclusions: The full ROB distribution was more extensive than was apparent on cone-beam CT. Quantitative measures of embolic distribution demonstrated significantly better correlation with microCT with decreasing kVp. Similarly, qualitative analysis of MIPs showed improved visualization of beads with decreasing kVp. These findings demonstrate the clinical value of 80 kVp and 100 kVp protocols in the imaging of radiopaque embolizations compared with 120 kVp. However, considerations on X-ray penetration and dose may favor use of 100 kVp imaging over 80 kVp.<br /> (Published by Elsevier Inc.)

Details

Language :
English
ISSN :
1535-7732
Volume :
29
Issue :
4
Database :
MEDLINE
Journal :
Journal of vascular and interventional radiology : JVIR
Publication Type :
Academic Journal
Accession number :
29500000
Full Text :
https://doi.org/10.1016/j.jvir.2017.11.011