Back to Search Start Over

Failed Blade Implant After 25 Years in Function: Case Description and Histologic Analysis.

Authors :
Farronato D
Fumagalli D
Asa'ad F
Pasini PM
Mangano F
Rasperini G
Source :
The International journal of periodontics & restorative dentistry [Int J Periodontics Restorative Dent] 2018 Mar/Apr; Vol. 38 (2), pp. e29-e32.
Publication Year :
2018

Abstract

This report describes a failed blade implant after 25 years in function in the left maxilla and the results of histologic analysis of peri-implant tissues. The blade was retrieved, and histologic findings revealed that it was not osseointegrated despite being successfully in function for so many years. The long-term function of blade implants without osseointegration can be attributed to biotolerance exhibited by the implant rather than actual osseointegration.

Details

Language :
English
ISSN :
1945-3388
Volume :
38
Issue :
2
Database :
MEDLINE
Journal :
The International journal of periodontics & restorative dentistry
Publication Type :
Academic Journal
Accession number :
29447315
Full Text :
https://doi.org/10.11607/prd.3384