Can Diagnostic and Therapeutic Arthrocentesis Be Successfully Performed in the Flexed Knee?

Authors :
Yaqub S
Sibbitt WL Jr
Band PA
Bennett JF
Emil NS
Fangtham M
Fields RA
Hayward WA
Kettwich SK
Roldan LP
Bankhurst AD
Source :
Journal of clinical rheumatology : practical reports on rheumatic & musculoskeletal diseases [J Clin Rheumatol] 2018 Sep; Vol. 24 (6), pp. 295-301.
Publication Year :
2018

Abstract

Background/objective: The objective of this study was to determine whether the extended or flexed knee positioning was superior for arthrocentesis and whether the flexed knee positioning could be improved by mechanical compression.<br />Methods: Fifty-five clinically effusive knees underwent arthrocentesis in a quality improvement intervention: 20 consecutive knees in the extended knee position using the superolateral approach, followed by 35 consecutive knees in the flexed knee position with and without an external compression brace placed on the suprapatellar bursa. Arthrocentesis success and fluid yield in milliliters were measured.<br />Results: Fluid yield for the extended knee was greater (191% greater) than the flexed knee (extended knee, 16.9 ± 15.7 mL; flexed knee, 5.8 ± 6.3 mL; P < 0.007). Successful diagnostic arthrocentesis (≥2 mL) was 95% (19/20) in the extended knee and 77% (27/35) in the flexed knee (P = 0.08). After mechanical compression was applied to the suprapatellar bursa and patellofemoral joint of the flexed knee, fluid yields were essentially identical (extended knee, 16.9 ± 15.7 mL; flexed knee, 16.7 ± 11.3 mL; P = 0.73), as were successful diagnostic arthrocentesis (≥2 mL) (extended knee 95% vs. flexed knee 100%, P = 0.12).<br />Conclusions: The extended knee superolateral approach is superior to the flexed knee for conventional arthrocentesis; however, the extended knee positioning and flexed knee positioning have identical arthrocentesis success when mechanical compression is applied to the superior knee. This new flexed knee technique for arthrocentesis is a useful alternative for patients who are in wheelchairs, have flexion contractures, cannot be supine, or cannot otherwise extend their knee.

Details

Language :
English
ISSN :
1536-7355
Volume :
24
Issue :
6
Database :
MEDLINE
Journal :
Journal of clinical rheumatology : practical reports on rheumatic & musculoskeletal diseases
Publication Type :
Academic Journal
Accession number :
29424762
Full Text :
https://doi.org/10.1097/RHU.0000000000000707