Back to Search
Start Over
Identification of optimal device combinations for the chimney endovascular aneurysm repair technique within the PERICLES registry.
- Source :
-
Journal of vascular surgery [J Vasc Surg] 2018 Jul; Vol. 68 (1), pp. 24-35. Date of Electronic Publication: 2018 Feb 01. - Publication Year :
- 2018
-
Abstract
- Objective: The ideal stent combination for chimney endovascular aneurysm repair remains undetermined. Therefore, we sought to identify optimal aortic and chimney stent combinations that are associated with the best outcomes by analyzing the worldwide collected experience in the PERformance of chImney technique for the treatment of Complex aortic pathoLogiES (PERICLES) registry.<br />Methods: The PERICLES registry was reviewed for patients with pararenal aortic disease electively treated from 2008 to 2014. Eleven different aortic devices were identified with three distinct subgroups: group A (n = 224), nitinol/polyester; group B (n = 105), stainless steel/polyester; and group C (n = 69), nitinol/expanded polytetrafluoroethylene. The various chimney stent subtypes included the balloon-expandable covered stent (BECS), self-expanding covered stent, and bare-metal stent. Deidentified aortic and chimney device combinations were compared for risk of chimney occlusion, type IA endoleak, and survival. Effects of high-volume centers (>100 cases), use of an internal lining chimney stent, number of chimney stents, and number of chimney stent subtypes deployed were also considered. We considered demographics, comorbidities, and aortic anatomic features as potential confounders in all models.<br />Results: The 1- and 3-year freedom from BECS chimney occlusion was not different between groups (group A, 96% ± 2% and 87% ± 5%; groups B and C, 93% ± 3% and 76% ± 10%; Cox model, P = .33). Similarly, when non-BECS chimney stents were used, no difference in occlusion risk was noted for the three aortic device groupings; however, group C patients receiving BECS did have a trend toward higher occlusion risk relative to group C patients not receiving a BECS chimney stent (hazard ratio [HR], 4.0; 95% confidence interval [CI], 0.85-18.84; P = .08). Patients receiving multiple chimney stents, irrespective of stent subtype, had a 1.8-fold increased risk of occlusion for each additional stent (HR, 1.8; 95% CI, 1.2-2.9; P = .01). Use of a bare-metal endolining stent doubled the occlusion hazard (HR, 2.1; 95% CI, 1.0-4.5; P = .05). Risk of type IA endoleak (intraoperatively and postoperatively) did not significantly differ for the aortic devices with BECS use; however, group C patients had higher risk relative to groups A/B without BECS (C vs B: odds ratio [OR], 3.2 [95% CI, 1-11; P = .05]; C vs A/B: OR, 2.4 [95% CI, 0.9-6.4; P = .08]). Patients treated at high-volume centers had significantly lower odds for development of type IA endoleak (OR, 0.2; 95% CI, 0.1-0.7; P = .01) irrespective of aortic or chimney device combination. Mortality risk was significantly higher in group C + BECS vs group A + BECS (HR, 5.3; 95% CI, 1.6-17.5; P = .006). The 1- and 3-year survival for groups A, B, and C (+BECS) was as follows: group A, 97% ± 1% and 92% ± 3%; group B, 93% ± 3% and 83% ± 7%; and group C, 84% ± 7% and 63% ± 14%. Use of more than one chimney subtype was associated with increased mortality (HR, 3.2; 95% CI, 1.4-7.5; P = .006).<br />Conclusions: Within the PERICLES registry, use of nitinol/polyester stent graft devices with BECS during chimney endovascular aneurysm repair is associated with improved survival compared with other aortic endografts. However, this advantage was not observed for non-BECS repairs. Repairs incorporating multiple chimney subtypes were also associated with increased mortality risk. Importantly, increasing chimney stent number and bare-metal endolining stents increase chimney occlusion risk, whereas patients treated at low-volume centers have higher risk of type IA endoleak.<br /> (Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Aged
Aged, 80 and over
Alloys
Aortic Aneurysm, Abdominal diagnostic imaging
Aortic Aneurysm, Abdominal mortality
Aortic Aneurysm, Thoracic diagnostic imaging
Aortic Aneurysm, Thoracic mortality
Blood Vessel Prosthesis Implantation adverse effects
Blood Vessel Prosthesis Implantation methods
Blood Vessel Prosthesis Implantation mortality
Comorbidity
Disease-Free Survival
Endoleak etiology
Endovascular Procedures adverse effects
Endovascular Procedures methods
Endovascular Procedures mortality
Europe
Female
Graft Occlusion, Vascular etiology
Hospitals, High-Volume
Hospitals, Low-Volume
Humans
Male
Multivariate Analysis
Odds Ratio
Polyesters
Polytetrafluoroethylene
Proportional Hazards Models
Prosthesis Design
Registries
Retrospective Studies
Risk Factors
Stainless Steel
Time Factors
Treatment Outcome
United States
Aortic Aneurysm, Abdominal surgery
Aortic Aneurysm, Thoracic surgery
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation instrumentation
Endovascular Procedures instrumentation
Stents
Subjects
Details
- Language :
- English
- ISSN :
- 1097-6809
- Volume :
- 68
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of vascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 29395423
- Full Text :
- https://doi.org/10.1016/j.jvs.2017.10.080