Back to Search
Start Over
Femoral Component Varus Malposition is Associated with Tibial Aseptic Loosening After TKA.
- Source :
-
Clinical orthopaedics and related research [Clin Orthop Relat Res] 2018 Feb; Vol. 476 (2), pp. 400-407. - Publication Year :
- 2018
-
Abstract
- Background: The notion that neutral alignment is mandatory to assure long-term durability after TKA has been based mostly on short-film studies. However, this is challenged by recent long-film studies.<br />Questions/purposes: We conducted this long-film study to know (1) whether the risk of aseptic revision for nontraumatic reasons was greater among knees with greater than 3° varus or valgus (defined as "outliers") than those that were aligned within 3° of neutral on long-standing mechanical axis (hip to knee) radiographs; and (2) what the failure mechanisms were and whether the malalignment was femoral or tibial in origin, or both, among those in the outlier group.<br />Methods: Between November 1998 and January 2009 we performed 1299 cemented, posterior cruciate ligament-substituting TKAs in 867 patients for primary osteoarthritis. We had inadequate long-standing radiographs to analyze postoperative alignment for 124 of those knees, and an additional 24 were excluded for prespecified reasons. Consequently, 1151 knees were enrolled in our study. Of these, 982 (85%) in 661 patients (620 women and 41 men) who had followup greater than 24 months were analyzed. The knees were divided according to whether the postoperative mechanical axis was neutral (0° ± 3°), varus (> 3°), or valgus (< -3°) alignment on long-standing radiographs. The survivorships free from aseptic revision for nontraumatic reasons were compared among groups. The mechanical femoral and the tibial component alignment (MFCA and MTCA, respectively) were investigated to know the origin of overall mechanical malalignment of the outlier knees. The mean duration of followup was 8 ± 4 years (range, 2-17 years). Thirty-five knees (4%) showed aseptic loosening at 7 ± 4 years (range, 0.1-14 years) and five (1%) showed polyethylene wear at 12 ± 1 years (range, 10-13 years). Tibial loosening (73%) was the most common reason for aseptic revision followed by femoral loosening (30%). Of this cohort, 687 (70%), 250 (25%), and 45 (5%) knees had overall mechanical neutral, varus, and valgus alignment, respectively. Factors associated with the risk of aseptic revision were identified by Cox regression.<br />Results: The varus outliers (but not the valgus outliers) failed more often than the neutral knees (10% [25 of 250] versus 2% [13 of 687]; odds ratio [OR], 5.8, 95% CI, 2.9-11.5; p < 0.001). Ten-year survivorship free from aseptic revision was lower among varus outliers than among knees with neutral alignment (87% [95% CI, 80%-93%] versus 98% [95% CI, 97%-99%]; p = 0.001). Femoral component varus malpositioning was the main origin of the varus outliers (MFCA = 4.2° ± 2.0°; MTCA = 0.9° ± 1.7°) and was a risk factor for aseptic revision compared with neutral femoral positioning (OR, 14.0; 95% CI, 1.9-105.6; p < 0.001).<br />Conclusions: This long-film study corresponds to previous short-film studies for the notion that varus malalignment is associated with inferior long-term implant survivorship. Although aseptic loosening occurred most commonly on the tibial side, the primary origin of the overall varus malalignment was femoral component varus malpositioning. Aiming for neutral alignment in TKA still seems to be a reasonable strategy in clinical practice.<br />Level of Evidence: Level III, therapeutic study.
- Subjects :
- Adult
Aged
Aged, 80 and over
Biomechanical Phenomena
Female
Humans
Knee Joint diagnostic imaging
Knee Joint physiopathology
Male
Middle Aged
Osteoarthritis, Knee diagnostic imaging
Osteoarthritis, Knee physiopathology
Prosthesis Design
Range of Motion, Articular
Reoperation
Retrospective Studies
Risk Assessment
Risk Factors
Time Factors
Treatment Outcome
Arthroplasty, Replacement, Hip adverse effects
Arthroplasty, Replacement, Hip instrumentation
Knee Joint surgery
Knee Prosthesis
Osteoarthritis, Knee surgery
Prosthesis Failure
Subjects
Details
- Language :
- English
- ISSN :
- 1528-1132
- Volume :
- 476
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Clinical orthopaedics and related research
- Publication Type :
- Academic Journal
- Accession number :
- 29389790
- Full Text :
- https://doi.org/10.1007/s11999.0000000000000012