Automatic patient positioning and gating window settings in respiratory-gated stereotactic body radiation therapy for pancreatic cancer using fluoroscopic imaging.
- Source :
-
Journal of applied clinical medical physics [J Appl Clin Med Phys] 2018 Mar; Vol. 19 (2), pp. 74-82. Date of Electronic Publication: 2018 Jan 27. - Publication Year :
- 2018
-
Abstract
- Before treatment delivery of respiratory-gated radiation therapy (RT) in patients with implanted fiducials, both the patient position and the gating window thresholds must be set. In linac-based RT, this is currently done manually and setup accuracy will therefore be dependent on the skill of the user. In this study, we present an automatic method for finding the patient position and the gating window thresholds. Our method uses sequentially acquired anterior-posterior (AP) and lateral fluoroscopic imaging with simultaneous breathing amplitude monitoring and intends to reach 100% gating accuracy while keeping the duty cycle as high as possible. We retrospectively compared clinically used setups to the automatic setups by our method in five pancreatic cancer patients treated with hypofractionated RT. In 15 investigated fractions, the average (±standard deviation) differences between the clinical and automatic setups were -0.4 ± 0.8 mm, -1.0 ± 1.1 mm, and 1.8 ± 1.3 mm in the left-right (LR), the AP, and the superior-inferior (SI) direction, respectively. For the clinical setups, typical interfractional setup variations were 1-2 mm in the LR and AP directions, and 2-3 mm in the SI direction. Using the automatic method, the duty cycle could be improved in six fractions, in four fractions the duty cycle had to be lowered to improve gating accuracy, and in five fractions both duty cycle and gating accuracy could be improved. Our automatic method has the potential to increase accuracy and decrease user dependence of setup for patients with implanted fiducials treated with respiratory-gated RT. After fluoroscopic image acquisition, the calculated patient shifts and gating window thresholds are calculated in 1-2 s. The method gives the user the possibility to evaluate the effect of different patient positions and gating window thresholds on gating accuracy and duty cycle. If deemed necessary, it can be used at any time during treatment delivery.<br /> (© 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.)
- Subjects :
- Humans
Image Processing, Computer-Assisted methods
Movement
Pancreatic Neoplasms diagnostic imaging
Prognosis
Radiotherapy Dosage
Radiotherapy, Intensity-Modulated methods
Respiration
Retrospective Studies
Fluoroscopy methods
Pancreatic Neoplasms surgery
Patient Positioning
Radiosurgery
Radiotherapy Planning, Computer-Assisted methods
Radiotherapy, Image-Guided methods
Respiratory-Gated Imaging Techniques methods
Subjects
Details
- Language :
- English
- ISSN :
- 1526-9914
- Volume :
- 19
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Journal of applied clinical medical physics
- Publication Type :
- Academic Journal
- Accession number :
- 29377561
- Full Text :
- https://doi.org/10.1002/acm2.12258