Back to Search
Start Over
Low Environmental Temperature Influences the Fatigue Resistance of Nickel-titanium Files.
- Source :
-
Journal of endodontics [J Endod] 2018 Apr; Vol. 44 (4), pp. 626-629. Date of Electronic Publication: 2018 Jan 03. - Publication Year :
- 2018
-
Abstract
- Introduction: The purpose of this study was to evaluate the effect of different temperatures (0°C, 10°C, 22°C, 37°C, and 60°C) on the cyclic fatigue life of nickel-titanium (NiTi) files using a new fatigue test model in zirconium oxide.<br />Methods: Three superelastic NiTi files (EndoSequence [Brasseler USA, Savannah, GA], ProFile [Dentsply Tulsa Dental Specialties, Tulsa, OK], and K3 [SybronEndo, Orange, CA]), and 3 heat-treated (K3XF [SybronEndo], Vortex [Dentsply Tulsa Dental Specialties], and HyFlex CM [Coltene-Whaledent, Allstetten, Switzerland]) NiTi files, all size 25/.04, were subjected to cyclic fatigue tests inside a novel, artificial ceramic canal with a curvature of 60° and a 5-mm radius. The model was immersed in water at 5 different preset temperatures. The number of cycles to failure (NCF) was recorded, and the fracture surface of the fragments was examined by a scanning electron microscope. The data were analyzed using 2-way analysis of variance with the significance level at 0.05.<br />Results: When the temperature was reduced from 60°C to 0°C, the NCF significantly increased from over 2 to 10 times for the NiTi file groups (P < .01). K3XF had the highest fatigue resistance of all files at 0°C (P < .05). Vortex files had the highest NCF at 10°C-60°C. The NCF of heat-treated files was significantly higher than superelastic NiTi files at 10°C and 20°C (P < .05). There was no significant difference in the NCF of HyFlex CM at 0°C and 22°C. There was little difference in the fractographic appearance among different temperatures, except that the fraction area occupied by the dimple region of some instruments at 0°C was slightly smaller than at 60°C.<br />Conclusions: Cooling down to low temperatures may be an interesting strategy to improve the fatigue resistance of rotary NiTi files.<br /> (Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1878-3554
- Volume :
- 44
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Journal of endodontics
- Publication Type :
- Academic Journal
- Accession number :
- 29306534
- Full Text :
- https://doi.org/10.1016/j.joen.2017.11.004