Back to Search
Start Over
Appropriate implantable cardioverter-defibrillator interventions in cardiac resynchronization therapy-defibrillator (CRT-D) patients undergoing device replacement: time to downgrade from CRT-D to CRT-pacemaker? Insights from real-world clinical practice in the DECODE CRT-D analysis.
- Source :
-
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2018 Sep 01; Vol. 20 (9), pp. 1475-1483. - Publication Year :
- 2018
-
Abstract
- Aim: Ventricular tachycardia (VT)/ventricular fibrillation (VF) occurrence after cardiac resynchronization therapy-defibrillator (CRT-D) replacement is unknown; hence, there is no practical guideline to recommend either CRT-D or CRT-pacemaker at the time of device replacement. We observed the 1-year VT/VF occurrence after CRT-D replacement in a subanalysis of the Detect Long-term Complications after ICD Replacement (DECODE) registry.<br />Methods and Results: A total of 332 consecutive patients who had undergone CRT-D replacement from 2013 to 2015 were enrolled in 36 Italian centres. The primary endpoint was the number of patients with any appropriate implantable cardioverter-defibrillator (ICD) interventions during 12-month follow-up. The secondary endpoint comprised death from any cause and appropriate ICD interventions. At replacement, 214 (64.5%) patients had a left ventricular ejection fraction ≤ 35% and 138 (41.6%) patients had a secondary prevention indication for ICD. Seventy (21.1%) patients had no longer indication to ICD therapy. During a median follow-up period of 406.5 (362-533) days, VT/VF requiring therapy delivery occurred in 57 (17%) patients, specifically in 7% of those who no longer had an ICD indication. On multivariate analysis, number of criteria for ICD replacement independently predicted appropriate ICD intervention during follow-up [hazard ratio (HR) = 1.62, 95% confidence interval (CI) 1.07-2.46; log-rank P = 0.02]. The combined endpoint of death from any cause or appropriate ICD therapy occurred in 76 (23%) patients. Only NYHA class remained associated with this combined endpoint (HR = 1.97, 95% CI 1.23-3.14; P = 0.005).<br />Conclusions: The DECODE registry showed the 'real-world' experience of CRT-D recipients approaching device replacement, in which 7% of patients who no longer had an indication for ICD therapy experienced appropriate ICD interventions.
- Subjects :
- Aged
Cardiac Resynchronization Therapy
Device Removal
Female
Humans
Italy
Male
Middle Aged
Practice Guidelines as Topic
Proportional Hazards Models
Stroke Volume
Atrial Fibrillation therapy
Cardiac Resynchronization Therapy Devices
Death, Sudden, Cardiac prevention & control
Defibrillators, Implantable
Prosthesis Implantation
Tachycardia, Ventricular epidemiology
Ventricular Fibrillation epidemiology
Subjects
Details
- Language :
- English
- ISSN :
- 1532-2092
- Volume :
- 20
- Issue :
- 9
- Database :
- MEDLINE
- Journal :
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 29186401
- Full Text :
- https://doi.org/10.1093/europace/eux323