[Reliability and reproducibility of introcular pressure (IOP) measurement with the Icare ® Home rebound tonometer (model TA022) and comparison with Goldmann applanation tonometer in glaucoma patients].

Authors :
Valero B
Fénolland JR
Rosenberg R
Sendon D
Mesnard C
Sigaux M
Giraud JM
Renard JP
Source :
Journal francais d'ophtalmologie [J Fr Ophtalmol] 2017 Dec; Vol. 40 (10), pp. 865-875. Date of Electronic Publication: 2017 Nov 22.
Publication Year :
2017

Abstract

Purpose: The Icare <superscript>®</superscript> Home tonometer is a new rebound tonometer, developed for intraocular pressure (IOP) self-monitoring. The main objective of our study was to evaluate the reliability and reproducibility of measurements taken with the Icare <superscript>®</superscript> Home tonometer in glaucoma patients compared to the Goldmann applanation tonometer. A secondary objective was to investigate factors that could influence the reproducibility of these measurements.<br />Materials and Methods: Fifty-two glaucoma patients were included in this prospective, non-randomized, monocentric study. IOP measurements were performed on the right eye and then on the left eye in the following order (3 measurements of IOP for each method): air tonometer (T-Air), Icare <superscript>®</superscript> Home tonometer by the patient (RT-P), Icare <superscript>®</superscript> Home tonometer by an ophthalmologist (RT-O), Goldmann applanation tonometer (GAT).<br />Results: Forty-four patients (85%) managed to take their IOP on both eyes with the Icare <superscript>®</superscript> Home tonometer. Mean IOPs were 14.35±3.93mmHg (T-Air), 13.43±4.65mmHg (RT-P), 14.13±4.29mmHg (RT-O), 14.74±3.84mmHg (GAT). The intraclass correlation indices (ICC) on the 3 repeated IOP measurements were 0.924, 0.872, 0.947 and 0.957, respectively. Bland-Altman analysis found a mean difference (bias) between GAT and RT-P, between GAT and RT-O, and between RT-O and RT-P, respectively, of 1.31, 0.61 and 0.70mmHg, with a 95% confidence interval of -3.34 to 5.96, -3.91 to 5.14 and -3.44 to 4.84mmHg, respectively. The reproducibility of the measurements taken with the Icare <superscript>®</superscript> Home tonometer did not vary according to corneal thickness or age of the patients.<br />Conclusion: The Icare <superscript>®</superscript> Home tonometer provides reliable and reproducible IOP values in glaucoma patients, although it appears to slightly underestimate the IOP measurements compared to the Goldmann applanation tonometer.<br /> (Copyright © 2017 Elsevier Masson SAS. All rights reserved.)

Details

Language :
French
ISSN :
1773-0597
Volume :
40
Issue :
10
Database :
MEDLINE
Journal :
Journal francais d'ophtalmologie
Publication Type :
Academic Journal
Accession number :
29174296
Full Text :
https://doi.org/10.1016/j.jfo.2017.06.008