Back to Search Start Over

Patient-Perceived and Laboratory-Measured Halos Associated with Diffractive Bifocal and Trifocal Intraocular Lenses.

Authors :
Alba-Bueno F
Garzón N
Vega F
Poyales F
Millán MS
Source :
Current eye research [Curr Eye Res] 2018 Jan; Vol. 43 (1), pp. 35-42. Date of Electronic Publication: 2017 Nov 21.
Publication Year :
2018

Abstract

Purpose: To examine and assess the halos generated in distance vision by multifocal intraocular lenses (IOLs) using both in vitro objective and in vivo subjective methods.<br />Setting: The objective method was carried out in the optics laboratory of the Applied Optics and Image Processing Group (Universitat Politècnica de Catalunya -Barcelona). The psychophysical and subjective methods were carried out in the Instituto de Oftalmología Avanzada Madrid Innova Ocular.<br />Design: Optical bench results and prospective evaluation of consecutive cases.<br />Methods: The IOLs examined were TECNIS <superscript>®</superscript> one-piece bifocals with addition powers of +4.00 D, +3.25 D, and +2.75 D and the trifocals AT-LISA-tri <superscript>®</superscript> and FineVision <superscript>®</superscript> . In the objective assessment, we examined halos around the far focus images of a pinhole formed by each IOL in an optical bench. For the in vivo study, we recruited 100 patients who had been bilaterally implanted one month earlier with the IOLs under study. Participants were subjected to psychophysical halometry (Halo v1.0) on the eye with better, distance-corrected, visual acuity and were required to subjectively grade halos by responding to the question "How much do halos bother you?"<br />Results: The objective method revealed that the halo size increased with addition power and that the two trifocals gave rise to a double-halo pattern. Scores in the halometry also indicated a direct relationship between the halo size and addition power. The subjective results indicated fewer complaints about halos associated with the trifocal than bifocal IOLs.<br />Conclusions: The addition power of the tested IOLs affected both laboratory-measured and patient-perceived halos. Trifocal lenses generated fewer complaints about halos. Precise: Multifocal intraocular lenses (MIOLs) give rise to halos observed by patients under conditions of dim lighting. This study compares laboratory characterized halos generated by five MIOLs with patient-perceived halos.

Details

Language :
English
ISSN :
1460-2202
Volume :
43
Issue :
1
Database :
MEDLINE
Journal :
Current eye research
Publication Type :
Academic Journal
Accession number :
29161162
Full Text :
https://doi.org/10.1080/02713683.2017.1379541