Back to Search Start Over

Prospective evaluation of poly-4-hydroxybutyrate mesh in CDC class I/high-risk ventral and incisional hernia repair: 18-month follow-up.

Authors :
Roth JS
Anthone GJ
Selzer DJ
Poulose BK
Bittner JG
Hope WW
Dunn RM
Martindale RG
Goldblatt MI
Earle DB
Romanelli JR
Mancini GJ
Greenberg JA
Linn JG
Parra-Davila E
Sandler BJ
Deeken CR
Voeller GR
Source :
Surgical endoscopy [Surg Endosc] 2018 Apr; Vol. 32 (4), pp. 1929-1936. Date of Electronic Publication: 2017 Oct 23.
Publication Year :
2018

Abstract

Background: Long-term resorbable mesh represents a promising technology for complex ventral and incisional hernia repair (VIHR). Preclinical studies indicate that poly-4-hydroxybutyrate (P4HB) resorbable mesh supports strength restoration of the abdominal wall. This study evaluated outcomes of high-risk subjects undergoing VIHR with P4HB mesh.<br />Methods: This was a prospective, multi-institutional study of subjects undergoing retrorectus or onlay VIHR. Inclusion criteria were CDC Class I, defect 10-350 cm <superscript>2</superscript> , ≤ 3 prior repairs, and ≥ 1 high-risk criteria (obesity (BMI: 30-40 kg/m <superscript>2</superscript> ), active smoker, COPD, diabetes, immunosuppression, coronary artery disease, chronic corticosteroid use, hypoalbuminemia, advanced age, and renal insufficiency). Physical exam and/or quality of life surveys were performed at regular intervals through 18 months (to date) with longer-term, 36-month follow-up ongoing.<br />Results: One hundred and twenty-one subjects (46M, 75F) with an age of 54.7 ± 12.0 years and BMI of 32.2 ± 4.5 kg/m <superscript>2</superscript> (mean ± SD), underwent VIHR. Comorbidities included the following: obesity (n = 95, 78.5%), hypertension (n = 72, 59.5%), cardiovascular disease (n = 42, 34.7%), diabetes (n = 40, 33.1%), COPD (n = 34, 28.1%), malignancy (n = 30, 24.8%), active smoker (n = 28, 23.1%), immunosuppression (n = 10, 8.3%), chronic corticosteroid use (n = 6, 5.0%), advanced age (n = 6, 5.0%), hypoalbuminemia (n = 3, 2.5%), and renal insufficiency (n = 1, 0.8%). Hernia types included the following: primary ventral (n = 17, 14%), primary incisional (n = 54, 45%), recurrent ventral (n = 15, 12%), and recurrent incisional hernia (n = 35, 29%). Defect and mesh size were 115.7 ± 80.6 and 580.9 ± 216.1 cm <superscript>2</superscript> (mean ± SD), respectively. Repair types included the following: retrorectus (n = 43, 36%), retrorectus with additional myofascial release (n = 45, 37%), onlay (n = 24, 20%), and onlay with additional myofascial release (n = 8, 7%). 95 (79%) subjects completed 18-month follow-up to date. Postoperative wound infection, seroma requiring intervention, and hernia recurrence occurred in 11 (9%), 7 (6%), and 11 (9%) subjects, respectively.<br />Conclusions: High-risk VIHR with P4HB mesh demonstrated positive outcomes and low incidence of hernia recurrence at 18 months. Longer-term 36-month follow-up is ongoing.

Details

Language :
English
ISSN :
1432-2218
Volume :
32
Issue :
4
Database :
MEDLINE
Journal :
Surgical endoscopy
Publication Type :
Academic Journal
Accession number :
29063307
Full Text :
https://doi.org/10.1007/s00464-017-5886-1