Back to Search Start Over

Pulmonary vein re-mapping after cryoballoon ablation for atrial fibrillation.

Authors :
Yokoyama K
Tokuda M
Matsuo S
Isogai R
Tokutake K
Kato M
Narui R
Tanigawa S
Yamashita S
Inada K
Yoshimura M
Yamane T
Source :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology [Europace] 2018 Jun 01; Vol. 20 (6), pp. 943-948.
Publication Year :
2018

Abstract

Aims: Establishment of pulmonary vein isolation (PVI) during cryoballoon (CB) ablation is generally confirmed by use of an octapolar inner-lumen mapping catheter (Achieve®). The aim of this study is to evaluate the residual PV potential (PVP) using the conventional circular catheter after CB-PVI.<br />Methods and Results: A total of 105 consecutive patients (418 PVs) with paroxysmal AF who underwent the initial CB-PVI were prospectively included in this study. Of those, 305 (73%) PVs with real-time recordings of PVP elimination by Achieve® catheter during successful PVI were included. After isolation of all 4 PVs, PV antral remapping by conventional circular mapping catheter was performed. After CB-PVI, residual PVP was detected in 4.3% (13/305) of PVs (1.2% of left-superior PV, 2.5% of left-inferior PV, none of right-superior PV, and 20% of right-inferior PV). Almost 60% of residual PV potential was located around the bottom portion of the right-inferior PV. In PVs with residual potential, PV trunk was shorter (12.7 ± 5.7 mm vs. 18.7 ± 7.9, P = 0.001), minimal balloon temperature was higher (-46.6 ± 5.9 °C vs. -50.9 ± 8.2, P = 0.02), and balloon warming time was shorter (35.6 ± 17.8 s vs. 50.0 ± 22.8, P = 0.006) than those without. All residual potentials were eliminated by additional touch up ablation. After the initial ablation procedure, 1-year AF-free rate was 79.5%.<br />Conclusion: PV remapping after CB-PVI revealed residual antral PVP in 4.3% of PVs and in 20% of RIPVs in particular. The Achieve® catheter sometimes fails to detect complete PV antral isolation.

Details

Language :
English
ISSN :
1532-2092
Volume :
20
Issue :
6
Database :
MEDLINE
Journal :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
Publication Type :
Academic Journal
Accession number :
29016768
Full Text :
https://doi.org/10.1093/europace/eux129