Back to Search
Start Over
Thoracic endovascular aortic repair migration and aortic elongation differentiated using dual reference point analysis.
- Source :
-
Journal of vascular surgery [J Vasc Surg] 2018 Feb; Vol. 67 (2), pp. 382-388. Date of Electronic Publication: 2017 Sep 21. - Publication Year :
- 2018
-
Abstract
- Objective: We evaluated images of patients undergoing a thoracic endovascular aortic repair procedure using two reference points as a means for differentiating stent graft migration from aortic elongation. Conventional standards define migration of a stent graft as an absolute change in the distance from the distal graft ring to a distal landmark ≥10 mm compared with a baseline measurement. Aortic elongation occurs over time in both healthy individuals and patients with aortic disease. Aortic elongation in patients with stent grafts may result in increased distal thoracic aortic lengths over time. False-positive stent graft migration would be defined when these patients meet the standard definition for migration, even if the stent has not moved in relation to the elongating aorta.<br />Methods: This retrospective study evaluated the aortic length of 23 patients treated with the conformable GORE TAG thoracic endoprosthesis (W. L. Gore & Associates, Flagstaff, Ariz) in three clinical trials (dissection, traumatic injury, and aneurysm). Patients who met the standard definition for migration were selected. A standardized protocol was used to measure aortic centerline lengths, including the innominate artery (IA) to the most distal device ring, the IA to the celiac artery (CA), and the distal ring to the CA. Baseline lengths obtained from the first postoperative image were compared with length measurements obtained from the first interval at which they met the standard definition for migration. The conventional standards for migration using a single reference point were compared with the use of dual reference points.<br />Results: Of the 23 patients with endograft changes, 20 were deemed to have aortic elongation rather than true migration. The remaining three patients were deemed to have migration on the basis of the IA to distal ring position compared with the IA to CA length change. The IA to CA interval length change was markedly greater in those with elongation compared with migration (23.8 ± 8.4 mm vs -3.5 ± 5.4 mm, respectively; P < .05). The distal ring to CA interval length change was greater in patients showing elongation rather than migration (18.5 ± 6.6 mm vs -9.8 ± 5.4 mm, respectively; P < .05). The distance between the IA and distal ring was similar for elongation and migration.<br />Conclusions: These results highlight the dynamic changes that can occur in the aorta as a natural consequence of age. Employing two landmarks can account for these changes and proves to be an important factor, among others, in the differentiation of aortic elongation from true stent graft migration.<br /> (Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Adult
Aged
Aged, 80 and over
Anatomic Landmarks
Aortic Dissection diagnostic imaging
Aorta, Thoracic diagnostic imaging
Aorta, Thoracic injuries
Aortic Aneurysm, Thoracic diagnostic imaging
Blood Vessel Prosthesis Implantation adverse effects
Endovascular Procedures adverse effects
Female
Foreign-Body Migration etiology
Humans
Longitudinal Studies
Male
Middle Aged
Predictive Value of Tests
Reproducibility of Results
Retrospective Studies
Treatment Outcome
Vascular System Injuries diagnostic imaging
Aortic Dissection surgery
Aorta, Thoracic surgery
Aortic Aneurysm, Thoracic surgery
Aortography methods
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation instrumentation
Computed Tomography Angiography
Endovascular Procedures instrumentation
Foreign-Body Migration diagnostic imaging
Stents
Vascular System Injuries surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1097-6809
- Volume :
- 67
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Journal of vascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 28943007
- Full Text :
- https://doi.org/10.1016/j.jvs.2017.07.108