Back to Search
Start Over
Electrocardiographic Markers of Appropriate Implantable Cardioverter-Defibrillator Therapy in Young People with Congenital Heart Diseases.
- Source :
-
Pediatric cardiology [Pediatr Cardiol] 2017 Dec; Vol. 38 (8), pp. 1663-1671. Date of Electronic Publication: 2017 Sep 04. - Publication Year :
- 2017
-
Abstract
- Implantable cardioverter-defibrillators (ICDs) are increasingly utilized in patients with congenital heart disease (CHD). Prediction of the occurrence of shocks is important if improved patient selection is desired. The electrocardiogram (ECG) has been the first-line tool predicting the risk of sudden death, but data in CHD patients are lacking. We aim to evaluate the predictive value of electrocardiographic markers of appropriate therapy of ICD in young people with CHD. We conducted a prospective, longitudinal study, in twenty-six CHD patients (mean age 24.7 ± 5.3 years) who underwent first ICD implantation. Forty-two age- and diagnosis-matched controls were recruited. Twelve-lead ECG and 24 h Holter analysis were performed during a mean follow-up of 38.9 months. Data included heart rate, heart rate variability, QRS duration (QRSd), QTc interval and its dispersion, Tpeak-Tend (Tp-Te) interval and its dispersion, presence of fragmented QRS (fQRS), T wave alternans, atrial arrhythmias, and non-sustained ventricular tachycardia. Implant indication was primary prevention in ten cases (38.5%) and secondary prevention in 16 (61.5%). Overall, 17 subjects (65.3%) received at least one appropriate and effective ICD discharge. fQRS was present in 64.7% of cases with ICD therapy compared with patients without events or controls (p < 0.0001). Tp-e and Tp-e dispersion were significantly prolonged in patients with recurrences (113.5 and 37.2 ms) versus patients without ICD discharge (89.6 and 24.1 ms) or controls (72.4 and 19.3 ms) (p < 0.0001 and p < 0.0001, respectively). On univariate Cox regression analysis QRSd (hazard ratio: 1.19 per ms, p = 0.003), QTc dispersion (hazard ratio: 1.57 per ms, p = 0.002), fQRS (hazard ratio: 3.58 p < 0.0001), Tp-e (hazard ratio: 2.27 per ms, p < 0.0001), and Tp-e dispersion (hazard ratio: 4.15 per ms, p < 0.0001), emerged as strong predictors of outcome. On multivariate Cox analysis fQRS, Tp-e and Tp-e dispersion remained in the model. The presence of fQRS, and both Tp-e and Tp-e dispersion are useful ECG tools in daily clinical practice to identify CHD patients at risk for appropriate ICD therapy.
- Subjects :
- Adult
Arrhythmias, Cardiac diagnosis
Arrhythmias, Cardiac mortality
Biomarkers
Cohort Studies
Death, Sudden, Cardiac etiology
Death, Sudden, Cardiac prevention & control
Female
Follow-Up Studies
Heart Defects, Congenital mortality
Heart Defects, Congenital therapy
Humans
Longitudinal Studies
Male
Predictive Value of Tests
Proportional Hazards Models
Prospective Studies
Risk Factors
Survival Analysis
Young Adult
Arrhythmias, Cardiac etiology
Defibrillators, Implantable adverse effects
Electrocardiography methods
Heart Defects, Congenital complications
Subjects
Details
- Language :
- English
- ISSN :
- 1432-1971
- Volume :
- 38
- Issue :
- 8
- Database :
- MEDLINE
- Journal :
- Pediatric cardiology
- Publication Type :
- Academic Journal
- Accession number :
- 28871362
- Full Text :
- https://doi.org/10.1007/s00246-017-1711-9