Back to Search Start Over

Diagnostic accuracy of optical coherence tomography for diagnosing glaucoma: secondary analyses of the GATE study.

Authors :
Virgili G
Michelessi M
Cook J
Boachie C
Burr J
Banister K
Garway-Heath DF
Bourne RRA
Asorey Garcia A
Ramsay CR
Azuara-Blanco A
Source :
The British journal of ophthalmology [Br J Ophthalmol] 2018 May; Vol. 102 (5), pp. 604-610. Date of Electronic Publication: 2017 Aug 30.
Publication Year :
2018

Abstract

Background/aims: To assess the diagnostic performance of retinal nerve fibre layer (RNFL) data of optical coherence tomography (OCT) for detecting glaucoma.<br />Methods: Secondary analyses of a prospective, multicentre diagnostic study (Glaucoma Automated Tests Evaluation (GATE)) referred to hospital eye services in the UK were conducted. We included data from 899 of 966 participants referred to hospital eye services with suspected glaucoma or ocular hypertension. We used both eyes' data and logistic regression-based receiver operator characteristics analysis to build a set of models to measure the sensitivity and specificity of the average and inferior quadrant RNFL thickness data of OCT. The reference standard was expert clinician examination including automated perimetry. The main outcome measures were sensitivity at 0.95 specificity and specificity at 0.95 sensitivity and the corresponding RNFL thickness thresholds. We explored the possibility of accuracy improvement by adding measures of within-eye and between-eye variation, scan quality, intraocular pressure (IOP) and age.<br />Results: Glaucoma was diagnosed in at least one eye in 17% of participants. Areas under the curve were between 0.83 and 0.88. When specificity was fixed at 0.95, the sensitivity was between 0.38 and 0.55, and the highest values were reached with models including the inferior quadrant rather than the average RNFL thickness. Fixing sensitivity at 0.95, the specificity was between 0.36 and 0.58. The addition of age, refractive error, IOP or within-subject variation did not improve the accuracy.<br />Conclusion: RNFL thickness data of OCT can be used as a diagnostic test, but accuracy estimates remain moderate even in exploratory multivariable modelling of aiming to improve accuracy.<br />Competing Interests: Competing interests: None declared.<br /> (© Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.)

Details

Language :
English
ISSN :
1468-2079
Volume :
102
Issue :
5
Database :
MEDLINE
Journal :
The British journal of ophthalmology
Publication Type :
Academic Journal
Accession number :
28855198
Full Text :
https://doi.org/10.1136/bjophthalmol-2017-310642