Abstract

Immunomagnetic separation (IMS) is an effective tool for the preconcentration and purification of food-borne pathogens from complex food samples because of its high capture efficiency (CE). In conventional IMS, antibodies are usually conjugated on the surface of magnetic beads (MB); the random orientation and conformation changes of antibodies on the MB surface can decrease their bioactivity. Moreover, the Brownian motion of immobilized antibodies is weakened, thereby rendering their binding efficiency with bacteria lower than that of free antibodies. Thus, abundant antibodies are commonly required to ensure high CE for IMS, particularly for large volumes. In this study, a 2-step large-volume magnetic separation (10 mL) was proposed to preconcentrate Listeria monocytogenes from pasteurized milk. First, the biotinylated anti-L. monocytogenes monoclonal antibodies (mAb) were bound with L. monocytogenes in 10 mL of diluted milk through an antigen-antibody interaction, and then streptavidin-labeled MB were used to capture biotin-mAb coated with L. monocytogenes by biotin and streptavidin interaction. Under optimal conditions, the CE of 2-step magnetic separation was >90% with L. monocytogenes concentrations ranging from 8 × 10 <superscript>0</superscript> to 8 × 10 <superscript>4</superscript> cfu/mL, whereas the amount of biotin-mAb was 14 fold lower than that of the conventional IMS method. Coupled with a PCR assay, the detection limit of the proposed method was 8 × 10 <superscript>0</superscript> cfu/mL in pure culture and 8 × 10 <superscript>1</superscript> cfu/mL in pasteurized milk without any pre-enrichment process. Moreover, the overall detection time, including sample preparation, large-volume magnetic separation, and PCR, took less than 7 h. In summary, the developed 2-step large-volume IMS combined with PCR was highly sensitive and low cost and, thus, has considerable potential for the rapid screening of food-borne pathogenic bacteria.<br /> (Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1525-3198
Volume :
100
Issue :
10
Database :
MEDLINE
Journal :
Journal of dairy science
Publication Type :
Academic Journal
Accession number :
28803008
Full Text :
https://doi.org/10.3168/jds.2017-13140