Back to Search
Start Over
Significance of a soft-coagulation system with monopolar electrode for hepatectomy: A retrospective two-institution study by propensity analysis.
- Source :
-
International journal of surgery (London, England) [Int J Surg] 2017 Sep; Vol. 45, pp. 149-155. Date of Electronic Publication: 2017 Jul 31. - Publication Year :
- 2017
-
Abstract
- Background: The VIO soft-coagulation system (VIO) with a monopolar electrode is a novel hemostatic device that provides hemostasis by superficial contact at the bleeding site without carbonization. Because heat injury remains a concern, surgical records and postoperative liver dysfunction were retrospectively evaluated in a cohort study.<br />Methods: Between September 2010 and March 2016, 322 patients underwent hepatectomy in which hemostatic devices were used at two institutions. Surgical results with use of VIO at one institute (VIO group) were compared with those without use of VIO at a second institute (control group), and propensity analysis was performed.<br />Results: In limited resection and segmentectomy or sectionectomy performed in the VIO group, the prevalence of liver cirrhosis was significantly higher and the operation time was significantly longer in comparison with the control group (p < 0.05). In all hepatectomies, postoperative levels of total bilirubin and aspartate or alanine transaminase tended to be increased and prothrombin activity tended to be lower in the VIO group in comparison with the control group (p < 0.05). The prevalence of hepatic failure in the VIO group was significantly higher in comparison with that in the control group (p < 0.05). In cases of segmentectomy or sectionectomy, blood loss was significantly increased in the VIO group in comparison with that in the control group (p < 0.05) Propensity score matching showed that although the surgical records and outcomes were not significantly different between the groups, postoperative liver dysfunction was significant in the VIO group in comparison with the control group (p < 0.05).<br />Conclusions: Mild postoperative hepatic thermal injury with VIO was confirmed, and therefore, surgeons should take care when using the VIO system to make frequent wide resected cuts on the surface of the liver.<br /> (Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.)
- Subjects :
- Aged
Alanine Transaminase blood
Bilirubin blood
Blood Coagulation Tests
Blood Loss, Surgical prevention & control
Electrodes
Female
Hemostasis, Surgical instrumentation
Humans
Liver Cirrhosis etiology
Male
Operative Time
Prothrombin metabolism
Retrospective Studies
Hemostasis, Surgical adverse effects
Hemostasis, Surgical methods
Hepatectomy adverse effects
Hepatectomy methods
Liver Diseases etiology
Subjects
Details
- Language :
- English
- ISSN :
- 1743-9159
- Volume :
- 45
- Database :
- MEDLINE
- Journal :
- International journal of surgery (London, England)
- Publication Type :
- Academic Journal
- Accession number :
- 28774659
- Full Text :
- https://doi.org/10.1016/j.ijsu.2017.07.101