Back to Search Start Over

Multiplexed analysis combining distinctly-sized CdTe-MPA quantum dots and chemometrics for multiple mutually interfering analyte determination.

Authors :
Bittar DB
Ribeiro DSM
Páscoa RNMJ
Soares JX
Rodrigues SSM
Castro RC
Pezza L
Pezza HR
Santos JLM
Source :
Talanta [Talanta] 2017 Nov 01; Vol. 174, pp. 572-580. Date of Electronic Publication: 2017 Jun 27.
Publication Year :
2017

Abstract

Semiconductor quantum dots (QDs) have demonstrated a great potential as fluorescent probes for heavy metals monitoring. However, their great reactivity, whose tunability could be difficult to attain, could impair selectivity yielding analytical results with poor accuracy. In this work, the combination in the same analysis of multiple QDs, each with a particular ability to interact with the analyte, assured a multi-point detection that was not only exploited for a more precise analyte discrimination but also for the simultaneous discrimination of multiple mutually interfering species, in the same sample. Three different MPA-CdTe QDs (2.5, 3.0 and 3.8nm) with a good size distribution, confirmed by the FWHM values of 48.6, 55.4 and 80.8nm, respectively, were used. Principal component analysis (PCA) and partial least squares regression (PLS) were used for fluorescence data analysis. Mixtures of two MPA-CdTe QDs, emitting at different wavelength namely 549/566, 549/634 and 566/634nm were assayed. The 549/634nm emitting QDs mixture provided the best results for the discrimination of distinct ions on binary and ternary mixtures. The obtained RMSECV and R <superscript>2</superscript> CV values for the binary mixture were good, namely, from 0.01 to 0.08mgL <superscript>-1</superscript> and from 0.74 to 0.89, respectively. Regarding the ternary mixture the RMSECV and R <superscript>2</superscript> CV values were good for Hg(II) (0.06 and 0.73mgL <superscript>-1</superscript> , respectively) and Pb(II) (0.08 and 0.87mg L <superscript>-1</superscript> , respectively) and acceptable for Cu(II) (0.02 and 0.51mgL <superscript>-1</superscript> , respectively). In conclusion, the obtained results showed that the developed approach is capable of resolve binary and ternary mixtures of Pb (II), Hg (II) and Cu (II), providing accurate information about lead (II) and mercury (II) concentration and signaling the occurrence of Cu (II).<br /> (Copyright © 2017 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-3573
Volume :
174
Database :
MEDLINE
Journal :
Talanta
Publication Type :
Academic Journal
Accession number :
28738624