Back to Search
Start Over
Fast and reproducible in vivo T 1 mapping of the human cervical spinal cord.
- Source :
-
Magnetic resonance in medicine [Magn Reson Med] 2018 Apr; Vol. 79 (4), pp. 2142-2148. Date of Electronic Publication: 2017 Jul 24. - Publication Year :
- 2018
-
Abstract
- Purpose: To develop a fast and robust method for measuring T <subscript>1</subscript> in the whole cervical spinal cord in vivo, and to assess its reproducibility.<br />Methods: A spatially nonselective adiabatic inversion pulse is combined with zonally oblique-magnified multislice echo-planar imaging to produce a reduced field-of-view inversion-recovery echo-planar imaging protocol. Multi- inversion time data are obtained by cycling slice order throughout sequence repetitions. Measurement of T <subscript>1</subscript> is performed using 12 inversion times for a total protocol duration of 7 min. Reproducibility of regional T <subscript>1</subscript> estimates is assessed in a scan-rescan experiment on five heathy subjects.<br />Results: Regional mean (standard deviation) T <subscript>1</subscript> was: 1108.5 (±77.2) ms for left lateral column, 1110.1 (±83.2) ms for right lateral column, 1150.4 (±102.6) ms for dorsal column, and 1136.4 (±90.8) ms for gray matter. Regional T <subscript>1</subscript> estimates showed good correlation between sessions (Pearson correlation coefficient = 0.89 (P value < 0.01); mean difference = 2 ms, 95% confidence interval ± 20 ms); and high reproducibility (intersession coefficient of variation approximately 1% in all the regions considered, intraclass correlation coefficient = 0.88 (P value < 0.01, confidence interval 0.71-0.95)).<br />Conclusions: T <subscript>1</subscript> estimates in the cervical spinal cord are reproducible using inversion-recovery zonally oblique-magnified multislice echo-planar imaging. The short acquisition time and large coverage of this method paves the way for accurate T <subscript>1</subscript> mapping for various spinal cord pathologies. Magn Reson Med 79:2142-2148, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.<br /> (© 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.)
- Subjects :
- Adult
Algorithms
Brain diagnostic imaging
Female
Healthy Volunteers
Humans
Image Interpretation, Computer-Assisted
Imaging, Three-Dimensional
Male
Motion
Phantoms, Imaging
Reproducibility of Results
Signal Processing, Computer-Assisted
Cervical Cord diagnostic imaging
Echo-Planar Imaging methods
Subjects
Details
- Language :
- English
- ISSN :
- 1522-2594
- Volume :
- 79
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Magnetic resonance in medicine
- Publication Type :
- Academic Journal
- Accession number :
- 28736946
- Full Text :
- https://doi.org/10.1002/mrm.26852