Back to Search Start Over

How does the use of multiple needles/syringes per injecting episode impact on the measurement of individual level needle and syringe program coverage?

Authors :
O'Keefe D
McCormack A
Cogger S
Aitken C
Burns L
Bruno R
Stafford J
Butler K
Breen C
Dietze P
Source :
The International journal on drug policy [Int J Drug Policy] 2017 Aug; Vol. 46, pp. 99-106. Date of Electronic Publication: 2017 Jun 28.
Publication Year :
2017

Abstract

Background: Recent work by McCormack et al. (2016) showed that the inclusion of syringe stockpiling improves the measurement of individual-level syringe coverage. We explored whether including the use of a new parameter, multiple sterile syringes per injecting episode, further improves coverage measures.<br />Methods: Data comes from 838 people who inject drugs, interviewed as part of the 2015 Illicit Drug Reporting System. Along with syringe coverage questions, the survey recorded the number of sterile syringes used on average per injecting episode. We constructed three measures of coverage: one adapted from Bluthenthal et al. (2007), the McCormack et al. measure, and a new coverage measure that included use of multiple syringes. Predictors of multiple syringe use and insufficient coverage (<100% of injecting episodes using a sterile syringe) using the new measure, were tested in logistic regression and the ability of the measures to discriminate key risk behaviours was compared using ROC curve analysis.<br />Results: 134 (16%) participants reported needing multiple syringes per injecting episode. Women showed significantly increased odds of multiple syringe use, as did those reporting injection related injuries/diseases and injecting of opioid substitution drugs or pharmaceutical opioids. Levels of insufficient coverage across the three measures were substantial (20%-28%). ROC curve analysis suggested that our new measure was no better at discriminating injecting risk behaviours than the existing measures.<br />Conclusion: Based on our findings, there appears to be little need for adding a multiple syringe use parameter to existing coverage formulae. Hence, we recommend that multiple syringe use is not included in the measurement of individual-level syringe coverage.<br /> (Copyright © 2017 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-4758
Volume :
46
Database :
MEDLINE
Journal :
The International journal on drug policy
Publication Type :
Academic Journal
Accession number :
28667880
Full Text :
https://doi.org/10.1016/j.drugpo.2017.05.055