Back to Search
Start Over
Endovascular Repair of Iatrogenic Iliocaval Fistula Causing High-Output Cardiac Failure after Spine Fusion.
- Source :
-
Annals of vascular surgery [Ann Vasc Surg] 2017 Nov; Vol. 45, pp. 262.e1-262.e5. Date of Electronic Publication: 2017 Jun 21. - Publication Year :
- 2017
-
Abstract
- The case being presented is a 35-year-old female with a 3-year history of progressive dyspnea and right-sided heart failure following spine surgery. Physical examination identified a continuous bruit in the lower abdomen radiating to her back which prompted further evaluation. Echocardiography showed normal left ventricle systolic function, enlarged right ventricle, functional tricuspid regurgitation, and moderate pulmonary hypertension. A computed tomography (CT) scan of the abdomen and pelvis demonstrated findings consistent with an arteriovenous fistula (AVF) between the right common iliac artery and the inferior vena cava. She underwent an uneventful endovascular repair without perioperative complication. The patient's symptoms resolved a few hours after the procedure and she continued to be symptom free at 3-month follow-up. This case illustrates an iatrogenic iliocaval fistula causing high-output cardiac failure which was successfully treated endovascularly with excellent clinical result.<br /> (Copyright © 2017 Elsevier Inc. All rights reserved.)
- Subjects :
- Adult
Arteriovenous Fistula diagnostic imaging
Arteriovenous Fistula etiology
Arteriovenous Fistula physiopathology
Blood Vessel Prosthesis
Cardiac Output, High diagnostic imaging
Cardiac Output, High physiopathology
Computed Tomography Angiography
Echocardiography, Doppler
Female
Heart Failure diagnostic imaging
Heart Failure physiopathology
Humans
Iliac Artery diagnostic imaging
Iliac Artery injuries
Iliac Artery physiopathology
Recovery of Function
Stents
Treatment Outcome
Vascular System Injuries diagnostic imaging
Vascular System Injuries etiology
Vascular System Injuries physiopathology
Vena Cava, Inferior diagnostic imaging
Vena Cava, Inferior injuries
Vena Cava, Inferior physiopathology
Arteriovenous Fistula surgery
Blood Vessel Prosthesis Implantation instrumentation
Cardiac Output
Cardiac Output, High etiology
Endovascular Procedures instrumentation
Heart Failure etiology
Iatrogenic Disease
Iliac Artery surgery
Spinal Fusion adverse effects
Vascular System Injuries surgery
Vena Cava, Inferior surgery
Subjects
Details
- Language :
- English
- ISSN :
- 1615-5947
- Volume :
- 45
- Database :
- MEDLINE
- Journal :
- Annals of vascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 28647630
- Full Text :
- https://doi.org/10.1016/j.avsg.2017.06.033