Back to Search
Start Over
Operative and 1-Year Outcomes of the Custom-Made Fenestrated Anaconda Aortic Stent Graft-A UK Multicenter Study.
- Source :
-
Annals of vascular surgery [Ann Vasc Surg] 2018 Jan; Vol. 46, pp. 257-264. Date of Electronic Publication: 2017 Jun 12. - Publication Year :
- 2018
-
Abstract
- Background: Early and 1-year outcomes are presented for fenestrated endovascular aneurysm repair (FEVAR) of complex aortic aneurysmal disease with the custom-made Anaconda fenestrated stent graft in 101 patients.<br />Methods: Retrospective site-reported data from the first 101 elective cases (2010-2014) from 4 UK centers were studied to evaluate patient demographics, aneurysm morphology, clinical success, and 1-year outcomes in patients undergoing fenestrated aneurysm repair with the custom-made Anaconda device.<br />Results: 101 fenestrated grafts (median age 76, 85% male) were implanted with a total of 255 fenestrations (196 renal arteries, 48 superior mesenteric artery, and 11 celiac arteries) with 3% mortality, 98.4% target vessel patency (TVP) at 30 day follow-up. Although 15 type I or III endoleaks were demonstrated at completion angiography, all 10 type Ia endoleaks resolved spontaneously. Survival by Kaplan-Meier analysis was 97% and 91% at 1 month and 1 year, respectively; with 75.8% showing reduction in abdominal aortic aneurysm diameter and only 1 patient with sac expansion. Freedom from loss of TVP was 97.6%.<br />Conclusions: Custom-made fenestrated Anaconda devices demonstrate low procedural mortality and a high rate of technical and clinical success at 30 days and 1 year.<br /> (Copyright © 2017 Elsevier Inc. All rights reserved.)
- Subjects :
- Aged
Aged, 80 and over
Aortic Aneurysm, Abdominal diagnostic imaging
Aortic Aneurysm, Abdominal mortality
Aortic Aneurysm, Abdominal physiopathology
Aortography methods
Blood Vessel Prosthesis Implantation adverse effects
Blood Vessel Prosthesis Implantation mortality
Computed Tomography Angiography
Disease-Free Survival
Endoleak etiology
Endovascular Procedures adverse effects
Endovascular Procedures mortality
England
Female
Humans
Kaplan-Meier Estimate
Male
Middle Aged
Multidetector Computed Tomography
Prosthesis Design
Retrospective Studies
Risk Factors
Time Factors
Treatment Outcome
Vascular Patency
Aortic Aneurysm, Abdominal surgery
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation instrumentation
Endovascular Procedures instrumentation
Stents
Subjects
Details
- Language :
- English
- ISSN :
- 1615-5947
- Volume :
- 46
- Database :
- MEDLINE
- Journal :
- Annals of vascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 28619356
- Full Text :
- https://doi.org/10.1016/j.avsg.2017.05.027