Back to Search
Start Over
Accuracy of a new intraoperative cone beam CT imaging technique (Artis zeego II) compared to postoperative CT scan for assessment of pedicle screws placement and breaches detection.
- Source :
-
European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society [Eur Spine J] 2017 Nov; Vol. 26 (11), pp. 2906-2916. Date of Electronic Publication: 2017 May 20. - Publication Year :
- 2017
-
Abstract
- Purpose: The goal of this study was to compare the accuracy of a novel intraoperative cone beam computed tomography (CBCT) imaging technique with that of conventional computed tomography (CT) scans for assessment of pedicle screw placement and breach detection.<br />Methods: Three hundred and forty-eight pedicle screws were inserted in 58 patients between October 2013 and March 2016. All patients had an intraoperative CBCT scan and a conventional CT scan to verify the placement of the screws. The CBCT and CT images were reviewed by two surgeons to assess the accuracy of screw placement and detect pedicle breaches using two established classification systems. Agreement on screw placement between intraoperative CBCT and postoperative CT was assessed using Kappa and Gwet's coefficients. Using CT scanning as the gold standard, the sensitivity, specificity, positive predictive value, and negative predictive value were calculated to determine the ability of CBCT imaging to accurately evaluate screw placement.<br />Results: The Kappa coefficient was 0.78 using the Gertzbein classification and 0.80 using the Heary classification, indicating a substantial agreement between the intraoperative CBCT and postoperative CT images. Gwet's coefficient was 0.94 for both classifications, indicating almost perfect agreement. The sensitivity, specificity, positive predictive value and negative predictive value of the CBCT images were 77, 98, 86, and 96%, respectively, for the Gertzbein classification and 79, 98, 88, and 96%, respectively, for the Heary classification.<br />Conclusions: Intraoperative CBCT provides accurate assessment of pedicle screw placement and enables intraoperative repositioning of misplaced screws. This technique may make postoperative CT imaging unnecessary.
- Subjects :
- Humans
Postoperative Period
Predictive Value of Tests
Retrospective Studies
Sensitivity and Specificity
Cone-Beam Computed Tomography methods
Cone-Beam Computed Tomography statistics & numerical data
Pedicle Screws
Spinal Fusion instrumentation
Spinal Fusion methods
Spinal Fusion statistics & numerical data
Surgery, Computer-Assisted instrumentation
Surgery, Computer-Assisted methods
Surgery, Computer-Assisted statistics & numerical data
Subjects
Details
- Language :
- English
- ISSN :
- 1432-0932
- Volume :
- 26
- Issue :
- 11
- Database :
- MEDLINE
- Journal :
- European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
- Publication Type :
- Academic Journal
- Accession number :
- 28528479
- Full Text :
- https://doi.org/10.1007/s00586-017-5139-y