Paclitaxel-Coated Balloons for the Treatment of Symptomatic Central Venous Stenosis in Dialysis Access: Results from a Randomized Controlled Trial.
- Source :
-
Journal of vascular and interventional radiology : JVIR [J Vasc Interv Radiol] 2017 Jun; Vol. 28 (6), pp. 811-817. Date of Electronic Publication: 2017 Apr 20. - Publication Year :
- 2017
-
Abstract
- Purpose: To compare the clinically-assessed intervention-free period (IFP) of paclitaxel-coated balloon (PCB) vs conventional balloon angioplasty (CBA) for the treatment of symptomatic central venous stenosis (CVS) in dialysis access.<br />Materials and Methods: Within 20 months, 40 dialysis patients (19/40 arteriovenous fistulae [AVFs] and 21/40 arteriovenous grafts [AVGs]) were randomized to undergo angioplasty either with a PCB (PCB group, n = 20; 14/20 male; age: 56.7) or CBA (CBA group, n = 20; 15/20 male; age: 57). There were 15/20 restenotic lesions in PCB group and 12/20 in CBA group. In 25/40 cases, patients had an ipslateral catheter insertion in the past. Primary endpoint was clinically-assessed intervention-free period (IFP) of the treated segment at 6 months, while secondary endpoints included complication rates during follow-up period and identification of factors influencing IFP.<br />Results: Median IFP was significantly better in PCB group (PCB group: 179 days, vs CBA group: 124.5 days, P = .026). Mean follow-up period was 180 days (range, 5-479). There was no significant difference between AVGs and AVFs (P = .17), treatment of de novo vs restenotic lesions (P = .33), or prior presence of catheter insertion (P = .21). No complications were observed. In restenotic lesions in PCB group, longitudinal comparison between treatments also showed a significant difference in favor of PCB treatment (median IFP in PCB* group 177 vs 91 days in CBA* group; P = .01).<br />Conclusions: In this prospective study, PCB had significantly better results compared with CBA for the treatment of symptomatic central venous stenosis in dialysis access. Retrospective longitudinal comparison of treatments in the same patients also showed a significant difference in favor of PCBs.<br /> (Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Adult
Aged
Aged, 80 and over
Arteriovenous Shunt, Surgical adverse effects
Coated Materials, Biocompatible
Female
Humans
Male
Middle Aged
Paclitaxel administration & dosage
Prospective Studies
Single-Blind Method
Treatment Outcome
Tubulin Modulators administration & dosage
Angioplasty, Balloon instrumentation
Graft Occlusion, Vascular drug therapy
Paclitaxel therapeutic use
Renal Dialysis
Tubulin Modulators therapeutic use
Subjects
Details
- Language :
- English
- ISSN :
- 1535-7732
- Volume :
- 28
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Journal of vascular and interventional radiology : JVIR
- Publication Type :
- Academic Journal
- Accession number :
- 28434662
- Full Text :
- https://doi.org/10.1016/j.jvir.2017.03.007