Highest dominant frequency and rotor positions are robust markers of driver location during noninvasive mapping of atrial fibrillation: A computational study.

Authors :
Rodrigo M
Climent AM
Liberos A
Fernández-Avilés F
Berenfeld O
Atienza F
Guillem MS
Source :
Heart rhythm [Heart Rhythm] 2017 Aug; Vol. 14 (8), pp. 1224-1233. Date of Electronic Publication: 2017 Apr 10.
Publication Year :
2017

Abstract

Background: Dominant frequency (DF) and rotor mapping have been proposed as noninvasive techniques to guide localization of drivers maintaining atrial fibrillation (AF).<br />Objective: The purpose of this study was to evaluate the robustness of both techniques in identifying atrial drivers noninvasively under the effect of electrical noise or model uncertainties.<br />Methods: Inverse-computed DFs and phase maps were obtained from 30 different mathematical AF simulations. Epicardial highest dominant frequency (HDF) regions and rotor location were compared with the same inverse-computed measurements after addition of noise to the ECG, size variations of the atria, and linear or angular deviations in the atrial location inside the thorax.<br />Results: Inverse-computed electrograms (EGMs) individually correlated poorly with the original EGMs in the absence of induced uncertainties (0.45 ± 0.12) and were worse with 10-dB noise (0.22 ± 0.11), 3-cm displacement (0.01 ± 0.02), or 36° rotation (0.02 ± 0.03). However, inverse-computed HDF regions showed robustness against induced uncertainties: from 82% ± 18% match for the best conditions, down to 73% ± 23% for 10-dB noise, 77% ± 21% for 5-cm displacement, and 60% ± 22% for 36° rotation. The distance from the inverse-computed rotor to the original rotor was also affected by uncertainties: 0.8 ± 1.61 cm for the best conditions, 2.4 ± 3.6 cm for 10-dB noise, 4.3 ± 3.2 cm for 4-cm displacement, and 4.0 ± 2.1 cm for 36° rotation. Restriction of rotor detections to the HDF area increased rotor detection accuracy from 4.5 ± 4.5 cm to 3.2 ± 3.1 cm (P <.05) with 0-dB noise.<br />Conclusion: The combination of frequency and phase-derived measurements increases the accuracy of noninvasive localization of atrial rotors driving AF in the presence of noise and uncertainties in atrial location or size.<br /> (Copyright © 2017 Heart Rhythm Society. All rights reserved.)

Details

Language :
English
ISSN :
1556-3871
Volume :
14
Issue :
8
Database :
MEDLINE
Journal :
Heart rhythm
Publication Type :
Academic Journal
Accession number :
28408329
Full Text :
https://doi.org/10.1016/j.hrthm.2017.04.017